DMD50 Universal Satellite Modem
c. NON-VOL: This will allow for setting up all required IP Addresses and will store the
information to the non-volatile memory. Upon power cycle, the modem will restore the
saved settings into the correct fields.
d. IP TEST: The IP Test selection is similar in behavior to the Default selection. When
enabled, the following preset parameters will be programmed and will not change until
the selection is changed. To edit these parameters, change the boot mode to NON-VOL.
The DMD50 is shipped from the factory with the Boot Mode configured as Default.
Verify that the Boot Mode is set for Default. To access the unit via the Ethernet port
set the selection to IP TEST. This will set the IP parameter to an accessible address. If
IMPORTANT
user wants to utilize an alternate address, user must set the selection to NON-VOL. As
an example, we will use a new modem IP address of 172.018.100.205 for the remaining of
the TCP-IP setup procedure. Contact the IT manager for proper guidance to ensure
setup is successful.
2. BOOT SERVER TAG: This allows for the selection of the operating boot tag when operating in
the BOOTp Mode. The default setting of 206 is automatically selected when the boot mode is set
to 'DEFAULT' (factory preset mode).
3. MODEM HOST: This displays the unit Host name that is operating, such as "DMD20". This is
a read only display.
4. IP ADDR MASK: This will allow for the entry of the IP Address Mask. This will need to be
entered based on the Network settings. Refer to your IP Administrator if you do not know this
address for the correct address setting. Example IP Address Mask setting: 255.255.000.000.
5. MODEM IP ADDR: This will allow for the entry of the Modem's individual network IP
Address. Each device on the network will have a unique address. Refer to the IT administrator
for the correct address setting. Example Modem IP Address setting: 172.018.100.215.
6. SERVER IP ADDR: This allows for the setup of the Network Server IP Address. This section
refers to the Host that will be used to optionally boot the DMD50 on power-up and is the SNMP
Trap Server. This IP Address needs to be consistent with the Modem IP Address. Broadcast and
loop back addresses will not be allowed. Example Server IP Address setting: 172.018.004.250.
7. ROUTER IP ADDR: This allows for the setup of the Network Router IP Address. If a router is
present on the local network, and it is to be used, this address must be consistent with the IP
Address Mask and the subnet of the modem. If no router is present, then the address should be
set to a foreign address. Broadcast and loop back addresses will not be allowed. Router not used
example: Router IP Address setting: 010.000.001.001.
8. MODEM EADDR: This displays the Modem (Unit) Ethernet Address. The Modem Ethernet
Address is configured at the factory. It is a unique Radyne equipment identifier Address.
Example: 0010650903EB
9. ETHER RATE: This displays the current Ethernet port data rate. If multiple rates are available,
then a selection can be made to specify the Ethernet port data rate (10BaseT). Example Ethernet
port Data Rate: 10 MBPS/HD
MN-DMD50 Revision 4
IP MASK
MODEM IP ADDR
SERVER IP ADDR
ROUTER IP ADDR
255.255.255.000
192.168.000.238
192.168.000.101
192.168.000.102
TCP/IP Ethernet Setup