Leveling The Xy Table (Cable Drive) - Stratasys Dimension 768/Elite Service Manual

Hide thumbs Also See for Dimension 768/Elite:
Table of Contents

Advertisement

Leveling the XY Table (Cable Drive)

Required Tools
1
" allen wrench
8
3
" allen wrench
8
5
" nut driver or standard screwdriver
16
• Head bracket
• Dial indicator
Leveling Procedure:
1. Power down the system using the power-down switch. Once the system is powered down,
switch the circuit breaker to the off position.
2. Unplug the AC power cord, RJ-45 network cable and UPS cable (if used) from the rear of
the printer.
3. Remove the rear door. See
4. Remove the side panels. See
1
5. Using a
" allen wrench, remove the 2 head cooling fan mounting screws. Set the fan off to
8
the side. See
Figure 23.
2 mounting screws
3
6. Using a
" allen wrench, remove the dial indicator mounting screw from the head bracket.
8
See
Figure 24.
"Removing the Rear Door:" on page 5-9.
"Side Panels" on page 5-11.
Figure 23: Head fan mounting screw locations
6-23