Each Setting And Adjustment; Adjustment Required When The Unit Is Repaired Or Replaced - Pioneer krp-m01 Service Manual

Table of Contents

Advertisement

5

8. EACH SETTING AND ADJUSTMENT

1. At shipment, the unit is adjusted to its best conditions. Normally, it is not necessary to readjust even if an assembly is replaced. If the
adjustment is shifted or if it becomes necessary to readjust because of part replacement, etc., perform the adjustment as described below.
2. Any value changed in Service/Factory mode will be stored in memory as soon as it is changed. Before readjustment, take note of the
original values for reference in case you need to restore the original settings.
3. Use a stable AC power supply.

8.1 ADJUSTMENT REQUIRED WHEN THE UNIT IS REPAIRED OR REPLACED

When any of the following assemblies is replaced
POWER SUPPLY Unit
MAIN BLOCK Assy (*)
Other assemblies
(*) : When replacing the MAIN BLOCK Assy, be sure to perform the FINAL SETUP.
Replacement of the whole Assy is required when one of the following part
on the corresponding Assy is in failure
PCB Assy No. Assy Name
AXY1204
POWER
SUPPLY Unit
AWV2570
MAIN BLOCK
Assy
AWV2572
AWV2571
FRONT_IO
(AWW1443)
Assy
5
6
Ref No.
Function Name
U0003
––
IC6403
DTV Flash
IC6001
SYSTEM IC (BCM7404)
IC5002
HDCP EEPROM
IC5003
HDCP EEPROM
IC5004
HDCP EEPROM
IC7301
FRONT HDCP EEPROM
IC7004
EMMA2 EEPROM
IC6701
ARIA FLASH
IC6811
IF UCOM
IC7202
EMMA2 FLASH
IC6201
BCM DDR SDRAM
IC6202
BCM DDR SDRAM
IC6203
BCM DDR SDRAM
IC6204
BCM DDR SDRAM
IC8501
PC EEPROM
KRP-M01
6
7
No adjustment required
Execute section [5-5] AUTO ADJUSTMENT of
6.2 [5] INITIALIZE.
No adjustment required
Part No.
––
The maker forbids Pioneer from repairing
the Assy.
S29GL512P10TFIR1
Because ID data (MAC address and data
-K (AGC1089)
on keys) have been stored
BCM7404XKPB11G-K
BR24L02FV-W
BR24L02FV-W
BR24L02FV-W
BR24L02FV-W
BR24L64F-W
S29GL016A90TFIR2
Because adjustments and data writing at
-K (AGC1088)
the level of production line are required
after replacement
AGC1086
S29GL032N90TFIO4
-K (AGC1087)
HY5DU121622DTP-D43-K
HY5DU121622DTP-D43-K
HY5DU121622DTP-D43-K
HY5DU121622DTP-D43-K
BR24L01AFJ-W
Because adjustments and data writing at the level
of production line are required after replacement
7
8
A
B
C
Reason
D
E
F
115
8

Hide quick links:

Advertisement

Table of Contents
loading