5

After analysis is finished

After analysis in Standalone Operation mode is finished, before returning the MR to the customer, be sure to return
the unit to System Operation mode, as shown in the procedures below.
If it remains in Standalone Operation mode, when it is connected with the customer's monitor, the monitor will detect
a connection error and not operate properly, and no image will be displayed.
To set the MR to System Operation mode, proceed as follows:
[With an RS-232C command]
1. Turn the MR on.
2. Send the MRMS00 command via RS-232C ports.
3. Turn the MR off.
When the MR is turned on next time or after, it will be in System Operation mode.
4. Connect the MR directly with the monitor and check that they operate properly.
[With the keys on the MR]
1. Set the MR to Standby mode.
2. Press and hold the INPUT key of the MR pressed for at least 5 seconds.
(This step is for giving a startup trigger in a case where the MR was in Passive Standby mode.)
3. Within 5 seconds after the INPUT key is released, press and hold the CHANNEL + key of the MR for at least 10 seconds.
4. After the modes are changed, the red LED flashes twice then is lit (the unit enters Normal Standby mode).
5. Turn the unit off.
When the MR is turned on next time or after, it will be in Standalone Operation mode.
Products whose proper operation has been proved
when HDMI connection is performed with this MR
Model Number
Manufacturer
PDP-5000EX
Pioneer
G8
Pioneer
FP241WJ
BenQ
3008WFP
DELL
HD2441W
EIZO NANAO

Attention point for audio volume

Audio output level is connected with MR volume level. If VR level of a MR is normal ( around 10 - 15) and displayed
HDMI TV or audio AMP is not so high level, sound level is very low. Please turn up the volume to appropriate level either
or both units.
In case of turning up volume of MR to very high level during testing, turn down it to normal level and then turn off the unit.
Otherwise when connecting the MR with panel, very loud sound is output from speakers and it might be a danger.

Attention point when using another Pioneer Plasma TV

Please pay attention to interference of IR signal when using Pioneer plasma TV as HDMI monitor.
If remote signal is also received to Pioneer plasma TV when operating MR with this tool and remote, you might confuse
of which unit is controlled by the remote.
The following methods are some of suggestions to control only MR with the conversion tool.
Using the remote control unit and the conversion tool ( AC adaptor connector ) as nearly as possible hiding remote sensor
of the plasma TV temporally.
Setting Method to connect with DVI monitor with HDCP support (DVI mode)
1. Open bonnet with power off condition.
2. Refer to Fig. 3, move the DIP SW No. [4] to ON side.
After this setting, DVI mode signal is output from HDMI output connector of HDMI.
Note: 1. Some of DVI monitors might not display output signal from this conversion tool.
2. Output signal does not contain digital audio signal.
5
6
Built-in Audio AMP
(SP is required)
(SP is required except 42 inch)
(External audio amp and SP is required)
(External audio amp and SP is required)
(External audio amp and SP is required)
KRP-M01
6
7
7
8
A
B
C
D
E
F
71
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents