Download  Print this page

Advertisement

1
A
OUTLINE OF POWER ON SEQUENCE
The rise of the output voltage is defined as the point at which 10% output voltage is reached,
and the fall is defined as the output supply stop point.
Sequence of AC ON (IN)
ON(IN)
AC
B
AC_DET
t1a
STB
RELAY
VCC
C
(a) Relay signal: When the POWER key on the remote control unit
is pressed after that on the unit is set to ON
AC ON
Item
AC to STB
RELAY to VCC
D
(b) Relay signal: When the POWER key on the remote control unit
is pressed while the unit is OFF (in Standby mode)
AC ON
Item
AC to STB
Relay to VCC
E
F
26
1
2
*1 For details on the rise sequence of Standby power voltages,
see "[3] DETAILS OF POWER ON SEQUENCE."
t2a
*2 For details on the rise sequence of Vcc power voltages,
see "[3] DETAILS OF POWER ON SEQUENCE."
Specified Time
t1a
0.8s
t2a
0.5s
Specified Time
t1a
0.8s
t2a No specification
2
3
KRP-M01
3
4
4