Download  Print this page

Advertisement

5
(3) Completion procedures for USB updating
After USB updating is completed, perform the following steps
(unplug the AC power cord, disconnect the USB memory
device, then plug the AC power cord back in).
On the MR
MR: USB updating completed
LED
Unplug the AC
power cord.
MR: AC OFF
LED
Disconnect the USB
memory device.
MR: AC OFF
LED
Plug in the AC
power cord.
MR: System Standby
LED
Turn the unit on, using
the Power key on the
remote control unit.
MR: Power ON
LED
List of frequency of LED (orange) flashing when updating fails
If updating is interrupted, the orange LED flashes to warn you of the error.
MR: USB updating error
LED
Frequency of
Error Content
Orange LED Flashing
1
(Not used)
2
Version error
3
USB update startup error
4
DTV Update Error
5
MAIN Download Error
6
ARIA Download Error
7
ZEUS Download Error
8
Module Download Error
9
IF Download Error
10
USB disconnection
11 to 13
Reserved
14
Destination error
Example: In a case where the orange LED flashes twice (version error)
Repetition of 1-sec flashing twice followed by a 2.5-sec pause (OFF)
0.5s
. 0
s 5
. 0
s 5
0.5s
1 1
2 2
Under the following conditions, USB updating procedures will be interrupted at Step 5 above, and normal startup will begin,
but the LED does not flash for error indication.
Conditions under which the LED will not flash for error indication
• Any USB updating file is damaged
• Not all USB updating files are stored in the USB memory device
• The USB updating files are modified
• The USB memory device is defective
5
6
On the Panel
Panel: Screen OFF
LED
Panel: MR AC OFF
LED
Pane: MR AC OFF
LED
Panel: No status change
LED
Panel: Screen ON
LED
The GUI indicating that updating
is completed is displayed.
The same version or a newer version of software has already been loaded.
Startup of USB updating failed.
Updating of the DTV software failed.
Updating of the MAIN microcomputer software failed.
Updating of the ASIC software in the previous stage failed.
Updating of the ASIC software in the later stage failed.
Updating of the module microcomputer software failed.
Updating of the IF microcomputer software failed.
Abnormality in the USB memory device
-
The software for a different destination (Europe/North America/Australia) was used for updating.
2.5s
. 0
s 5
. 0
s 5
. 0
s 5
. 0
s 5
1 1
2 2
KRP-M01
6
7
(3) Completion procedures for USB updating
After USB updating is completed, perform the following steps
(unplug the AC power cord, disconnect the USB memory
device, then plug the AC power cord back in).
On the MR
MR: USB updating completed
MR: No status change
Return the MR to System Operation mode, by sending a command via
the RS-232C connector.
How to set: Send the "MRMS00" command via the RS-232C connector.
In Standalone Operation mode of the MR, the GUI indicating that
updating is completed is not displayed.
Details
7
8
LED
Unplug the AC power cord.
MR : AC OFF
LED
Disconnect the USB
memory device.
LED
119
8
A
B
C
D
E
F

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0