5
PRIMARY
DC +120V to +390V
Logic Signal Specifications
[Logic level] H: STB3.4 V × (0.8 to 1.1), L:
Signal Name
I/O
RELAY
IN
Relay ON/OFF
PD_TRG
OUT
Determination of abnormality
inside the POWER SUPPLY Unit
AC_DET
OUT
AC detection
5
6
AC_DET CIRCUIT
STB3.4 V × 0.2
Function
H
L
Open
H
L
H
L
6
7
POWER
THERMISTOR
FUSE
Logic
Description
ON
For controlling ON/OFF of all output
OFF
signals other than STB signals
OFF
Determination
For sending a deterministic signal when an abnormality
of abnormality
is generated inside the POWER SUPPLY Unit to shut off
any output signals other than STB signals
Normal
Present
For detecting the presence of the AC input voltage,
regardless of ON/OFF of STB 3.4 V output
Absent
KRP-M01
7
8
P1
LIVE
AC IN
85 to 276V
NEUTRAL
8
A
B
C
D
E
F