Programming The Level 1 Functions (On-Off Functions); Level 2 Functions (Adjustable Parameters); Programming The Level 2 Functions (On-Off Functions) - Nice RD400 Instructions And Warnings For Installation And Use

For sliding gates
Hide thumbs Also See for RD400:
Table of Contents

Advertisement

7.6.2 - Programming the Level 1 functions (ON-OFF functions)

By default, Level 1 functions are all set to "OFF" but can be modified at any time as described in Table 6. Take care during modification proce-
dures, as there is a maximum time interval of 10 seconds between pressing of different buttons; otherwise the procedure terminates automati-
cally and stores the changes made up to that time.
01.
Press and hold Set for roughly 3 s
02.
Release the Set button when LED L1 starts flashing
Press and release the s/t button to shift the flashing LED to the LED representing the function to be
03.
modified
Press and release the Set button to change the status of the function
04.
(short flashing = OFF; long flashing = ON)
05.
Wait 10 seconds to exit the programming mode after the maximum time interval
Steps 03 and 04 can be repeated during the programming phase to set other functions to ON or OFF

7.6.3 - Level 2 functions (adjustable parameters)

LED
Parameter
L1
Motor force
Function
L2
Step-by-Step
L3
Pause Time
Note: the parameters with a grey background are default settings
All the parameters can be adjusted as required without any contraindications; only the adjustment of "motor force" could require special attention:
• Do not use high force values to compensate for points of abnormal friction on the leaf. Excessive force can compromise the operation of the
safety system or damage the leaf.
• If the "motor force" control is used to assist the impact force reduction system, measure the force again after each adjustment in compliance
with the EN 12453 and EN 12445 standards.
• Wear and weather conditions may affect the gate's movement, therefore periodic force readjustments may be necessary.
7.6.4 - Level 2 programming (adjustable parameters)
The adjustable parameters are set by default as shown in Table 7 with: " " but can be changed at any time as shown in Table 8. Take care dur-
ing modification procedures, as there is a maximum time interval of 10 seconds between pressing of different buttons; otherwise the procedure
terminates automatically and stores the changes made up to that time.
01.
Press and hold Set for roughly 3 s
02.
Release the Set button when LED L1 starts flashing
03.
Press and release the s/t buttons to shift the flashing LED to the LED representing the function to be
modified
04.
Keep the Set pressed down until Step 06
05.
Wait roughly 3 seconds after which the LED associated with the current level of the parameter to be
modified will light up
06.
Press and release the s/t buttons to shift the LED representing the parameter's value
07.
Release Set
Table 6 - Procedure for changing the Level 1 functions
Table 7 - Level 2 functions (adjustable parameters)
Level
Value
Low
L1
Medium
L2
High
L3
L1
Open - Stop - Close - Open
L2
Open - Stop - Close - Stop
L3
Condominium
L1
15 seconds
L2
30 seconds
L3
60 seconds
Table 8 - Procedure for changing the Level 2 functions
SET
Description
Adjusts the sensibility of the motor force control
to suit the type of gate. The "High" setting is more
suitable for heavier and larger gates
Adjusts the sequence of commands associated
with the "Step-by-Step" input or the 1st radio
command (see Tables 5 and 6)
Adjusts the pause time, that is, the time that
elapses before automatic re-closure. Is effective
only if automatic closure is enabled
(
(
SET
SET
3 s
L1
SET
10 s
3 s
SET
L1
SET
SET
)
SET
)
SET
English – 15