Fujitsu M2266S Technical Handbook page 62

Table of Contents

Advertisement

M2266S/H
Technical Handbook
(1)
Table 3.8 Setting Terminal: CNH1
Setting item
Pin position
Setting contents
LED display
requirements
1-2
Short Operating with the SCSI bus
Open READY (seek completion) status
3-4
5-6
7-8
9-10
}
The user cannot change the setting
UNIT
ATTENTION
report mode
11-12
Short Responds with CHECK CONDITION
status
Open Does not respond with CHECK
CONDITION status
SCSI time
monitoring mode
13-14 15-16
ACK signal wait
monitoring time
SELECTION
monitoring time and
number of retries
Short Short
oo
(unlimited)
250 ms, 128 retries
Short Open 30
-
60 sec
250 ms, 10 retries
Open Short 30 60 sec
250 ms, unlimited
retries
Open Open 1
-
2 sec
1 ms, 10 retries
*: Setting at factory shipment
(1) Refer to unit attention report mode explanation.
Fujitsu America, Inc.
FS810125-01 . . . A
3-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

M2266h

Table of Contents