Factory Terminal Settings
The following paragraphs list the terminal settings at factory shipment. The
terms "short" and "open" have the following meaning:
Short:
The short plug is mounted between specified pins on either
CN3 or CN9 as indicated.
Open:
The short plug is removed from between specified pins on
both CN3 and CN9.
Table 3.1 Setting Terminal: CN3/CN9
Setting item
Pin position
Setting contents
SCSI ID
9-10
11-12
13-14
SCSI ID
0
2
3
4
5
6
7
Open
Open
Open
Open
Short
Short
Short
Short
Open
Open
Short
Short
Open
Open
Short
Short
Open
Short
Open
Short
Open
Short
Open
Short
SCSI time monitoring
(RESELECTION, ACK response)
7-8
Open
Time monitoring is disabled.
Short
Time monitoring is enabled.
Read-Ahead caching
5
Open
Disabled
Short
Enabled
3-4
O pen
(Reserved, do not remove)
Short
Diagnostic switch
1-2
0pei
Diagnostics are executed
(diagnostic mode).
Short
Diagnostics stops (normal
operation mode).
Setting at factory shipment (CN9)
3-8
F5810125-01 . . . A