B1220, B1620, B1820, WSM
(6) Relay (2M) (With OPC Type)
(7) Starter Relay
Connector Voltage
1. Disconnect the connector from the relay (2M) after turning the
main switch off.
2. Apply the battery voltage between terminal 1 and 2.
3. Check for continuity between terminal 3 and 5.
4. Check for continuity between terminal 6 and 7.
5. If ohm is not indicated, renew the relay (2M).
(1) Relay (2M)
Starter Relay
1. Remove the panel board and starter relay (1).
2. Apply battery voltage across 2 terminal and 4 terminal, and
check for continuity across 1 terminal and 3 terminal.
3. If 0 Ω is not indicated, renew the starter relay (1).
1 terminal –
Resistance
3 terminal
(1) Starter Relay
9-S15
ELECTRICAL SYSTEM
9Y1210272ELS0079US0
Battery
voltage is
applied
across 2
0 Ω
terminal
and 4
terminal
1 to 4 : Terminals
9Y1210272ELS0015US0
KiSC issued 07, 2011 A
(EU)