Factory Reset; Network Port; Connecting Alarms - Revo R16DVR3 User Manual

16 channel
Table of Contents

Advertisement

User's Manual
Connecting the Observation Camera Power Cord
The CAMERA power connector is provided to supply power to the observation cameras. Connect the
connector of the adaptor to the DVR, and connect the AC power cord to the adaptor and then to the
wall outlet.

Factory Reset

CAUTION: When using the Factory Reset, you will lose any settings you have saved.
To reset the unit, you will need a straightened paperclip:
Turn the DVR off.  Poke the straightened paperclip in the unlabeled hole to the left of the Network port, and turn
the DVR on.  Hold the switch until the DVR turns on and the live monitoring screen appears.  Release the reset
switch. All of the DVR's settings are now at the original settings it had when it left the factory.

Network Port

The DVR can be networked using the 10/100Mb Ethernet connector. Connect a Cat5 cable with an RJ-45
jack to the DVR connector. The DVR can be networked with a computer for remote monitoring, searching,
configuration and software upgrades. See the Network Setup section in this chapter for configuring the
Ethernet connections.
CAUTION: The network connector is not designed to be connected directly with cable or wire
intended for outdoor use.

Connecting Alarms

Alarm In 1 to 16: You can use external devices to signal the DVR to react to events. Mechanical or electrical switches
can be wired to the ALARM IN and GND (Ground) connectors. The threshold voltage for NC (Normally Closed) is
above 4.3V and for NO (Normally Open) is below 0.3V, and it should be stable at least 0.5 seconds to be detected.
GND (Ground): Connect the ground side of the alarm input and/or alarm output to a GND connector.
NOTE: All the connectors marked GND are common.
NO (Normally Open): Connect the device to the COM and NO (Normally Open) connector. NO is a relay output
which sinks 1A@30VDC (NO).
Connector Pin Outs:
Connecting to the RS-485 Port
The RS-485 connector can be used to control PTZ (pan, tilt, zoom) cameras. Connect TX+/RX+ or TX-/RX-
of the control system to the + or – (respectively) of the DVR. See the Camera Setup section in this chapter
of this manual and the PTZ camera manufacture's manual for configuring the RS-485 connection.
4
The DVR has a Factory Reset switch to the left of the Network port on the rear panel. This
switch will only be used on the rare occasions that you want to return all the settings to the
original factory settings.
NOTE: To make connections on the Alarm Connector Strip, press and hold the button
and insert the wire in the hole below the button. After releasing the button, tug gently
on the wire to make certain it is connected. To disconnect a wire, press and hold
the button above the wire and pull out the wire.
Alarm In (1 to 16)
GND
COM
NO
Alarm Inputs 1 to 16
Chassis Ground
Common
Alarm Out (Normally Open)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents