Siemens Codoor CD3500 Installation & User Manual page 16

Hide thumbs Also See for Codoor CD3500:
Table of Contents

Advertisement

Available languages

Available languages

1
CD3500 & CD4000 Installation and User manual
Button 3
Button 4
Button 5
Button 6
Button 7
Button 8
Button 9
Button *
Button 0
Button #
Reset but-
ton on rear
Note!
The reset function can only be used when in test mode!
Checks the non-volatile memory (non destructively). If
successful a confirm tone is given or if unsuccessful an
error tone is given. The unit returns to test mode with
the green LED continuously lit.
Fires the solenoid in and out every 4 seconds, the
status of reed switch sensor is given on the LEDs, with
contact locked given by the green LED and unlocked
given by the red LED.
Puts the unit into sleep mode to enable the current con-
sumption of the unit to be measured. The unit will come
out of this function when any key is pressed.
Only shows the status of the position sensor. Red LED
– unit locked (solenoid un-engaged), green LED - unit
unlocked (solenoid engaged).
Puts the unit into an unlocked state with the status of
the position sensor shown on the LEDs as previously
stated.
Shows the status of the low battery input. Low battery
detected the red LED will show. If the battery voltage is
OK the green LED will show.
Does nothing except beep and light the red LED.
Does nothing except beep and light the red LED.
Does nothing except beep and light the red LED.
Exits test mode with a confirm tone, leaving all the data
intact in the non-volatile memory.
By pressing and holding the reset for 2 seconds the
Codoor's memory is cleared back to factory settings:
No programming code set.
No access codes set.
Buzzer enabled.
Deactivation function enabled.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Codoor cd4000

Table of Contents