5.5.2 DETECTION

CANERA
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11
DETECTION

ALERT

NETWORK
DISPLAY
RECORD
DEVICES
DCCS
IVS
NOTIFY
EXIT
1)
LS (Level of Sensitivity)
"LS" is to set the sensitivity of comparing two different images. The smaller the value is, the higher sensitivity
for motion detection. The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default
value is 07.
2)
SS (Spatial Sensitivity)
"SS" is to set the sensitivity for detecting the size of one object (the number of the grids) on the screen. The
smaller the value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 03.
Note: The default setting of SS is 03, which means once an object is detected more than 3 grids, the
system will get triggered. So the value of SS must be less than the number of grids that you set
up for the motion detection area.
3)
TS (Time of Sensitivity)
"TS" is to set the sensitivity regarding how long one object stays in the detection area and triggers the
recording. The smaller the value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 02.
4)
MOTION
Select if you want to activate the motion detection function for the selected channel (ON/OFF).
5)
ALARM
Select N.C./ N.O depending on your installation need. The default alarm value is OFF.
6)
AREA
Click "EDIT" to set the motion detection area.
There are 16 × 12 grids per camera for all channels. Pink blocks represent the area that is not being
detected while the transparent blocks are the area under detection.
5.5.3 ALERT
CANERA
DETECTION
ALERT
NETWORK
DISPLAY
RECORD
DEVICES
DCCS
IVS
NOTIFY
EXIT
ADVANCED CONFIG
LS
SS
TS
MOTION
ALARM
AREA
ADVANCED CONFIG
EXT. ALERT
INT. BUZZER
KEY BUZZER
VLOSS BUZZER
MOTION BUZZER
ALARM BUZZER
HDD BUZZER
ALARM DURATION (SEC)
HDD NEARLY FULL (GB)
07
03
02
OFF
OFF
EDIT
ON
OFF
ON
ON
ON
ON
ON
5
5
24
MAIN MENU