QUALIFIED
INSTALLER
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA, and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installations.
Conversion between fuels may only be done using the
approved conversion kits listed in the Options section.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install this
appliance.
This appliance, when installed with the optional
circulating fan kit (blower), must be electrically
grounded in accordance with local codes, or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
Model (Field convertible Top
or Rear Vent Outlet)
Gas
Altitude (Ft)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure
(in w.c.)
Maximum Supply Pressure
(in w.c.)
Main Burner Injector
Marking
Pilot Injector Marking
*High Altitude Installations
I nput ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
18
18
Specifi cations
MF28JN
MF28JP
Natural
Propane
0-4,500 feet*
26,000
26,000
6,500
14,500
3.75
9.0
5.0
11.0
11.0
14.0
82-750
92-300
35
27
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial
and/or local authorities having jurisdiction.
Supply Gas
Heater engine MF28JN is used with natural gas.
Heater engine MF28JP is used with propane gas.
The supply pressure must be between the limits
shown in the Ratings section above.
The supply connection is 3/8" NPT female.
5/16" O.D.
tubing
5/16"
fl are
3/8" N.P.T.
Female
Electrical
The Madrona stove does not require an electrical
power source unless it is fi tted with an optional
circulating fan—see page 28.
Hearth Requirements
This unit is approved for mounting directly on combus-
tible wood fl ooring. If installed directly on carpeting,
vinyl or soft combustible fl oor other than wood, it must
be installed on a metal or wood panel covering a mini-
mum surface of 15 inches deep by 28 inches width.
Madrona Stoves
There are two types of stove casing for the Madrona
MF28J engine, a traditional style available in two colors
and a contemporary style. The stove casings are sold
separately.
MFCS01—Traditional Stove Black, arched or square
fronted
MFCS02—Traditional Stove Majolica Brown, arched
or square fronted
MFCS04—Contemporary Stove
Traditional Stove—arched or square
fronted MFCS01 or MFCS02
3/8" N.P.T.
Contemporary Stove
MFCS04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: