Valor MADRONA MF28JN Installation & Owner's Manual

Dv gas fireplace heater (engine only)
Hide thumbs Also See for MADRONA MF28JN:

Advertisement

DV Gas Fireplace Heater (engine only)
Engine to be installed ONLY with the cast stove body MFCS01, MFCS02 or MFCS04
DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
4005005-02
©2016, Miles Industries Ltd. All rights reserved.
M
ADRONA
MF28JN (NG) & MF28JP (LPG)
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the
ENGINE ONLY. A stove casing is REQUIRED
to install the engine. A barrier screen is provided
with the stove casing. Refer to the manual sup-
plied with the stove casing for installation.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor MADRONA MF28JN

  • Page 1 ADRONA DV Gas Fireplace Heater (engine only) MF28JN (NG) & MF28JP (LPG) Engine to be installed ONLY with the cast stove body MFCS01, MFCS02 or MFCS04 Installation & Owner’s Manual DANGER I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Detector requirements on page 16. responsibility for any consequential damage(s). Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2016...
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully Due to the high temperature, the appliance should be before starting the installation. FAILURE TO FOLLOW LOCATED out of traffi c areas and away from furniture these installation instructions may result in possible fi re and draperies.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, A physical barrier is strongly • recommended if there are young Parts of your Valor Fireplace become • children, or at-risk individuals in the extremely hot while in operation. house. Install an approved after- The glass viewing window •...
  • Page 5: Owner's Information

    For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages is fully tested during the production process for your 3 and 4 of this manual BEFORE operating safety and comfort.
  • Page 6: Cleaning Your Stove

    OWNER’S Owner’s Information INFORMATION Cleaning Your Stove To remove the window for cleaning: 1. Traditional arched front stoves MFCS01 and WARNING MFCS02: Remove the barrier screen by pulling it on each side and then unhooking the top clip. DO NOT TOUCH THE GLASS WHILE IT IS HOT! Traditional square front stoves MFCS01 and Let the stove cool fi...
  • Page 7 fi replace, damage components, cause overheating resulting in dangerous conditions. WARNING Damage caused by incorrect window installa- tion is not covered by the Valor warranty. FOR SAFETY PURPOSE, ensure the barrier screen is re-installed on the stove front after maintenance.
  • Page 8: Checking Pilot And Burner Flames

    OWNER’S Owner’s Information INFORMATION Cast concrete stove body The appliance area must always be kept clear and Dust down the surface regularly with a soft brush and free from combustible materials, gasoline and other occasionally follow up with a wipe over with a wet cloth. fl...
  • Page 9: Locating Lighting, Operation And Rating Information Card

    OWNER’S Owner’s Information INFORMATION Locating Lighting, Operation and Rating If the fl ames are on, they go down and you hear the valve motor wind down. You hear a clunk and a beep Information Card indicating that the valve has received the signal from WARNING the remote control.
  • Page 10: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 11 OWNER’S Remote Control Operation INFORMATION MODES OF OPERATION • Press and hold (small fl ame) button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” TEMPERA- SETTING THE “DAYTIME” TEMPERATURE TURE Default Settings: (sun), 23ºC / 74ºF Default Settings: (moon), “ ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 13 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 14: Options

    OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ 6:00 a.m.— ☼ ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 15: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 16: Commonwealth Of Massachusetts

    OWNER’S Commonwealth of Massachusetts INFORMATION State of Massachusetts Carbon Monoxide building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for Detector/Vent Terminal Signage the horizontally vented gas fueled heating appliance Requirements or equipment.
  • Page 17 OWNER’S Commonwealth of Massachusetts INFORMATION requirements shall be satisfi ed by the manufacturer: 1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
  • Page 18: Specifi Cations

    QUALIFIED Specifi cations INSTALLER Approval & Codes For installations at elevations above 4,500 feet (1,370 m) in Canada, please consult provincial This appliance is certifi ed to ANSI Z21.88-2014/ and/or local authorities having jurisdiction. CSA 2.33-2014 American National Standard / CSA Standard for Vented Gas Fireplace Heaters for use in Supply Gas Canada and USA, and to CGA 2.17-91 High Altitude...
  • Page 19: Dimensions & Clearances

    QUALIFIED Dimensions & Clearances INSTALLER Traditional Cast Stove MFCS01 (black) or Traditional Cast Stove MFCS02 (Majolica brown)— arched or square fronted Suggested gas line 2” (52 mm) 4” access point through wall. minimum (102 mm) Route to avoid optional fan. Ø...
  • Page 20 QUALIFIED Dimensions & Clearances INSTALLER Contemporary Cast Stove MFCS04 Suggested gas line 1” (26 mm) 3-7/8” access point through wall. minimum (98 mm) Route to avoid optional fan. 10” (254 mm) Ø 6-5/8” venting Pipe supplied with engine (see engine manual p.
  • Page 21: Venting

    QUALIFIED Venting INSTALLER Top / Rear Outlet Wall Thickness This unit is shipped with a top outlet collar which is The appliance vent is suitable for penetrating a fi eld-convertible to rear outlet—see page 29 for details. combustible wall assembly up to 14 inches (36 cm) in thickness.
  • Page 22 QUALIFIED Venting INSTALLER Typical Venting Components See list of approved venting pipes and accessories on pages 39–40. Maximum pipe length: 24” (straight out with snorkel) 14” (45° elbow out with snorkel) Snorkel required (min. 14” high) with horizontal run through the wall (no rise) No more than one 45°...
  • Page 23 QUALIFIED Venting INSTALLER How to Read the Venting Chart 4. A maximum of 5 x 90 degrees elbows or equivalent (2 x 45 degrees = 90 degrees) can be used. The chart below applies to top or rear outlet, roof or 5.
  • Page 24 QUALIFIED Venting INSTALLER Restrictors The chart on the previous page shows the vent restrictor required relative to the length of the vent pipe. SOME INSTALLATIONS REQUIRE RESTRICTORS. Restrictors are not required for co-linear applications. For improved fl ame picture and performance, this unit To install restrictors: is supplied with two different sets of vent restrictors.
  • Page 25 QUALIFIED Venting INSTALLER Horizontal Vent Termination Location or a safety hazard. Local codes or regulations may require greater clearances. • The vent terminal must be located on an outside • The vent terminal must not be recessed into a wall wall or through the roof.
  • Page 26: Installation Planning

    QUALIFIED Venting INSTALLER Vertical Vent Termination Roof Minimum Pitch "H" (feet) Flat to 7/12 Over 7/12 to 1.5' 8/12 Over 8/12 to 2’ 9/12 Over 9/12 to 2.5’ 10/12 Over 10/12 to 3.25’ 11/12 Over 11/12 to 4’ 12/12 Over 12/12 to 5’...
  • Page 27: Remove Window

    QUALIFIED Installation INSTALLER Remove Window Fit Gas Pipe & Connector It is easier the remove the window and all the items Fit the pipe and connector supplied with the engine to packed inside of the fi rebox to make the engine lighter the valve.
  • Page 28: Install Fan (If Used)

    QUALIFIED Installation INSTALLER Install Fan (if used) 7. With 2 screws from the burner plate, fi x the fan’s thermoswitch to the underside of the burner plate, If the Circulating Fan Kit (blower) is to be installed, we behind the pilot area. suggest that you do it now.
  • Page 29: Convert Vent Outlet (If Necessary)

    QUALIFIED Installation INSTALLER Convert Vent Outlet (if necessary) If the appliance is to be vented from the top, it is ready for vent installation once the engine is on the casting base. If the appliance is to be vented from the rear, it must be converted.
  • Page 30: Connect Gas Supply

    QUALIFIED Installation INSTALLER Connect Gas Supply • When testing for leaks: • Make sure that the appliance is turned off. • The gas supply inlet connection is a 3/8 inch • Open the manual shut-off valve. NPT female connector. For detailed location of •...
  • Page 31: Install Traditional Log Set Mf28Lsk

    QUALIFIED Installation INSTALLER Install Traditional Log Set MF28LSK 3. Place the top left log on the pin of the rear log. The bottom of the log rests on the left side end of the Material required front left log just installed. •...
  • Page 32 QUALIFIED Installation INSTALLER 4. Place the front right log on the burner and slide it to 6. Place the lower end of the center right log onto the the left against the front left log. pin on the front right log. Rest the narrow end in the notch into the rear log.
  • Page 33: Install Driftwood Set Mf28Dwk

    QUALIFIED Installation INSTALLER Install Driftwood Set MF28DWK 2. Identify the rear log and place it on top of the base log locating it into the notches on top of the log. Pull Material required the log forward so it is locked in position. •...
  • Page 34 QUALIFIED Installation INSTALLER 4. Identify the left side cross log which has one pin at one end. Insert the pin in the hole at the front left of the platform and rests the top part of the log into the notch of the rear log as indicated.
  • Page 35: Refi T And Check Window

    WARNING Failure to install the window correctly can leak carbon monoxide, affect the performance of the fi replace, damage components, cause overheating resulting in dangerous conditions. Damage caused by incorrect window installa- tion is not covered by the Valor warranty.
  • Page 36: Synchronize Remote Control

    QUALIFIED Installation INSTALLER Synchronize Remote Control The receiver and the handset of the remote control system must be initially synchronized before the fi rst use. 1. Insert alkaline batteries in the remote control receiver and handset. The receiver is located left of the control valve under the burner module.
  • Page 37: Install Front And Barrier Screen

    QUALIFIED Installation INSTALLER Install Front and Barrier Screen When installing the front of the stove make sure you install as well the barrier screen provided with the cast stove body. Show the customer how to remove the barrier screen and how to access the controls. Follow the instructions provided with the stove cast body and leave those instructions behind for the customer’s further reference.
  • Page 38: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Optional Wall Switch Kit 1265WSK Connector Yellow GV60 Wiring Diagram...
  • Page 39: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 530 , 534, 650 and MF28 Venting Parts Code / availability by Manufacturer Venting Parts Description Standard Co-axial 46DVA-HC 4DT-HC TM-4HT — — 4DHC round 658DVK2 940160 Deluxe Co-axial —...
  • Page 40 658TG Notes: 1. All listed above co-axial pipes and fi ttings require Valor 817VAK Adapter Kit to fi t Valor’s smooth collars (Valor adapter 4DSC-V by American Metal Products may also be used). 2. Follow instructions supplied with each manufacturer’s components.
  • Page 41: Warranty

    The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase. Alternatively, the warranty registration form may be fi lled out online at www.valorfi replaces.com. b) Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation instructions.
  • Page 42: Spare Parts

    OWNER’S Spare Parts INFORMATION Description Part. no. Description Part. no. Traditional Log Set MF28LSK Pilot Shield 4000144 Rear Log 4003803 Pilot Gasket 4000139 Left Top Log 4003796 Pilot Mount 4000138 Right Top Log 4003797 Pilot Mount Gasket 4000140 Right Center Log 4003798 Pipe—Valve to Main Burner (incl.
  • Page 43 OWNER’S Spare Parts INFORMATION 56a, 56b...
  • Page 45: Miles Industries Ltd

    Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 46: Miles Industries Ltd

    Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

Madrona mf28jp

Table of Contents