6.10 Low-Temperature Circuit

6.10.1 Mixture coolant level – Check
Preconditions
☑ Engine is stopped and starting disabled.
☑ MTU Fluids and Lubricants Specifications (A001061/..) are available.
WARNING
Coolant is hot and under pressure.
Risk of injury and scalding!
• Let the engine cool down.
• Wear protective clothing, gloves, and goggles / safety mask.
Checking mixture coolant level
1.
Read off system filling pressure for 100 kW/cylinder (→ Page 24) or for 110 kW/cylinder (→ Page 29) at
pressure gauge.
2.
If required, top up with treated engine coolant (→ Page 168) .
164 | Task Description | MS150122/00E 2015-07