1.4530.011 – PWM Input Low Duty Cycle Error
Yellow alarm. Initiated by F-Series.
Cause
F-Series setting is not correct.
1.4530.012 – Analog Input High Error
Yellow alarm. Initiated by F-Series.
Cause
F-Series setting is not correct.
1.4530.013 – Analog Input Low Error
Yellow alarm. Initiated by F-Series.
Cause
F-Series setting is not correct.
1.4530.014 – Input Supply Voltage High Error
Yellow alarm. Initiated by F-Series.
Cause
Supply voltage has reached
maximum limit value.
1.4530.015 – Input Supply Voltage Low Error
Yellow alarm. Initiated by F-Series.
Cause
Supply voltage has reached
minimum limit value.
1.4530.016 – Electronics Temperature High Error
Red alarm. Initiated by F-Series.
Cause
Hardware not ready for operation.
1.4530.017 – Electronics Temperature Low Error
Red alarm. Initiated by F-Series.
Cause
Hardware not ready for operation.
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
1. Check supply voltage.
2. Check cabling.
Corrective action
u Restart F-Series.
Corrective action
u Restart F-Series.