MTU 20V4000Lx2x Operating Instructions Manual page 83

Table of Contents

Advertisement

1.4520.263 – Open Primary, Channel 18
Yellow alarm. Initiated by IC922.
Cause
Ignition energy was not
discharged.
1.4520.264 – Open Primary, Channel 19
Yellow alarm. Initiated by IC922.
Cause
Ignition energy was not
discharged.
1.4520.265 – Open Primary, Channel 20
Yellow alarm. Initiated by IC922.
Cause
Ignition energy was not
discharged.
1.4520.270 – Warn. Missing Ring Gear Signal
Yellow alarm. Initiated by IC922.
Cause
Crankshaft signal 182 teeth is
missing.
1.4520.271 – Warning Missing Reset Signal
Yellow alarm. Initiated by IC922.
Cause
Reset signal from crankshaft is
missing.
1.4520.272 – Warn. Missing Camshaft Signal
Yellow alarm. Initiated by IC922.
Cause
Missing camshaft signal for
ignition system.
1.4520.273 – SCR Fault Odd
Red alarm. Initiated by IC922.
Cause
Hardware not ready for operation.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coils.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coils.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coils.
Corrective action
u Check sensor B13.3, sensor distance and cabling; replace if
necessary.
Corrective action
u Check sensor B75, sensor distance and cabling; replace if
necessary.
Corrective action
u Check sensor B 1.2, sensor distance and cabling; replace if
necessary.
Corrective action
u Restart ignition.
MS150122/00E 2015-07 | Troubleshooting | 83

Advertisement

Table of Contents
loading