MTU 20V4000Lx2x Operating Instructions Manual page 67

Table of Contents

Advertisement

112519 – HIHI T-Exhaust B9
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112520 – HIHI T-Exhaust B10
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high in comparison with weighted
average.
112601 – LOLO T-Exhaust A1
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
112602 – LOLO T-Exhaust A2
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
112603 – LOLO T-Exhaust A3
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.
MS150122/00E 2015-07 | Troubleshooting | 67

Advertisement

Table of Contents
loading

Table of Contents