112711 – HIHI T-Exhaust B1 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high.
112712 – HIHI T-Exhaust B2 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high.
112713 – HIHI T-Exhaust B3 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high.
112714 – HIHI T-Exhaust B4 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high.
112715 – HIHI T-Exhaust B5 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high.
112716 – HIHI T-Exhaust B6 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
high.
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 143).
3. Check valve drive (exhaust valves do not close).