6.11.4 Sensor – Installation
Special tools, Material, Spare parts
Designation / Use
Torque wrench, 10–60 Nm
Ratchet adapter
Assembly compound (Kluthe Hakuform 30-15)
O-ring
Sealing ring
Sealing ring
Installing NOx sensor (B88)
Note:
After an impact or knock, the sensor is usual-
ly defective and must no longer be used.
1.
Do not remove protective cap from thread
until directly before assembly.
Note:
Do not wipe off the thread grease from the
manufacturer. If necessary, coat thread with
high-temperature anti-corrosion thread
grease. Too much grease can contaminate
the sensor during operation. Disassemble
and assemble sensor a maximum of two
times.
2.
Manually screw sensor into bore.
3.
Tighten nut (3) with torque wrench to specified tightening torque .
Name
Sensor
4.
If necessary, roll up sensor cable to correct length and secure with cable ties.
5.
Screw on electronics box (1) at the eyelets.
6.
Connect connector (2) and engage it.
176 | Task Description | MS150122/00E 2015-07
Size
Type
M20 x 1.5 Tightening torque
Part No.
F30452769
F30027340
X00067260
(→ Spare Parts Catalog)
(→ Spare Parts Catalog)
(→ Spare Parts Catalog)
Lubricant
Value/Standard
50 Nm ±10 Nm
Qty.
1
1
1