112404 – LO T-Exhaust A4
Yellow alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
112405 – LO T-Exhaust A5
Yellow alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
112406 – LO T-Exhaust A6
Yellow alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
112407 – LO T-Exhaust A7
Yellow alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
112408 – LO T-Exhaust A8
Yellow alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is too
low in comparison with weighted
average.
60 | Troubleshooting | MS150122/00E 2015-07
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 143).
4. Check valve drive.