GMC 1976 ZEO 6083 Maintenance Manual page 681

Table of Contents

Advertisement

24C- 4
ONAN MOTOR GENERATOR
C .
ENGINE RUNS 3 OR 4 SECONDS - THEN STOPS*
YES
NO
1C .
Check oil level . Refill to FULL mark on dipstick . Does engine now continue
to run?
-
2C
2C .
Check voltage from terminal 11 to 12 . Is it 12 volts with engine stopped
and does voltage drop to zero when engine runs?
-
3C
3C .
Check oil pressure sensor wire for shorts to ground by visually tracing
wire from S2 low oil pressure switch to control . Is wire grounded?
4C
5C
4C .
Replace or repair wire making sure it isn't rubbing against anything
that may again cause a grounding problem .
-
-
5C .
Replace low oil pressure switch S2 .
-
-
NOTE : Remote control leads may be shorted or grounded .
D.
LOW BATTERY - LOW CHARGE RATE
YES
NO
1D .
With engine cranking, measure voltage at terminal 8 to BAT terminal of
K1 start solenoid . Is 6 volts present?
2D
3D
2D .
Check battery connections . They must be clean and tight .
-
-
3D .
Check flywheel alternator G1 output. Disconnect AC lead that connects
to voltage regulator VR1 and connect voltmeter to this lead and BAT
terminal of K1 start solenoid . This checks AC open circuit voltage . Start
engine. Is AC output voltage approximately 28 volts with unit running at
1800 rpm?
5D
4D
4D .
Replace alternator stator G1 .
-
-
5D .
Connect a voltmeter across battery terminals . Start engine . Does DC
voltage increase to 13 to 14-112 volts after engine is running for a few
minutes?
-
6D
6D .
Remove and replace voltage regulator VR1 .
-
-