  • Page 1 Trapeze CTP-E48BSX CTP-E54BSX CTP-E60BSX Model number: Serial Number: Date of Purchase: Sales Dealer: JAN14.0101 © 2014 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Hood Specifi cations ........... Blower Preparation 9-11 ............. Mounting the Range Hood 12-14 ........FEATURES & CONTROLS Touch Controls ............. Features ................
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE IN OUTDOOR COOKING ENVIRONMENTS. CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
  • Page 6: Installation

    MODEL: CTP-E48BSX, CTP-E54BSX, CTP-E60BSX 1 - Hood 2 - Baffl e Filters 4 - 6W Zephyr Bloom™ HD LED Light Bulbs 2 - Telescopic Duct Covers 4 - Telescopic Support Rod Sets 4 - Telescopic Support Rod Couplers 1 - Duct Cover Ceiling Bracket...
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used Total length x used Total 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7” Round, 1 Ft. 6”- 8” Round, 30 Ft.
  • Page 8 www.zephyronline.com long reducer instead of a pancake reducer. Reduce duct size as far away from opening as possible. If turns or transitions are required; install as far away from opening and as far apart, between 2, as possible. Minimum mount height between range top and hood x .
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options External Blower side wall cap...
  • Page 10 www.zephyronline.com Top View Side View 32” Standard Duct Cover Min 34” - Max 51 1/2” Z1C-00TP Extension Min 47” - Max 72” 15-3/4” Ceiling Bracket Front View 11-3/4” 10” 13/16” 9” 1/2” 5/8” 12-1/8” FRONT 47-15/16”, 53-15/16”, 59-1/8”...
  • Page 11: Blower Preparation

    INTERNAL BLOWER PREPARATION 1. Remove internal blower fl ange from motor 2. Secure internal blower to internal blower fl ange by (4) M4*16 screws from internal blower housing by (6) screws. hardware. 3. Secure AC power wiring box to internal blower 4.
  • Page 12: Blower Preparation

    www.zephyronline.com INTERNAL BLOWER PREPARATION CONT. 8. Connect 6 pin molex connector from capacitor 7. Secure motor housing to hood body by (12) M4*6 cable to 6 pin molex connector from control box. screws. Connect 2 pin plug from AC power cable to 2 pin plug from control box.
  • Page 13 REMOTE BLOWER PREPARATION CONT. 4. Secure remote blower 8” round collar to remote 3. Secure AC power ground wire and remote blower fl ange by (8) M4*8 screws. blower ground wire to underside of remote blower fl ange by (1) 3/16*3/8 screw and (1) washer each.
  • Page 14 www.zephyronline.com Tabs Add Blockings Tabs Ceiling Bracket FIG. 1 Ceiling Mounting Holes Marking for Coupler Set screw mounting hole FRONT Electrical wiring FIG. 2 passage 1. Determine the location for mounting the hood. Mark centerlines front to back and left to right of hood placement. Place supplied paper template on ceiling and center marked center lines with template center lines.
  • Page 15 FIG. 4 FIG. 3 7. Determine desired height of hood, measure and select either 27 3/8” or 35 3/8” angle brackets. Position and attach angle brackets type A and B to the motor housing as shown using (8) M4*6 screws, (2) for each angle bracket.
  • Page 16 www.zephyronline.com Telescopic Rod Installation screws 1. Install telescopic rod (thicker end down) into coupler on top of hood and secure by (1) M4*4 set screw for each rod. 2. Extend inner telescopic rod to ceiling coupler and attach by (1) M4*4 set screw for each rod.
  • Page 17: Features

    Display (Speed level, Delay Off Indicator) Blower On/Off 15 Min Delay Off Adjust 3 Speed Levels Lights On/Dim/Off Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower and lights turn on at the same setting they were switched off at.
  • Page 18 www.zephyronline.com Baffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory, These baffle filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
  • Page 19: Maintenance

    The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. 1. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
  • Page 20 www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scoring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain.
  • Page 21: Troubleshooting

    TROUBLESHOOTING PROCEDURES FOR TRAPEZE Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 22 www.zephyronline.com VOLTS MAX AMPS CTP-E48/54/60BSX CBI290A 0.8 CBI600A 2.7 INTERNAL BLOWER CIRCUIT DIAGRAM...
  • Page 23 VOLTS MAX AMPS CTP-E48/54/60BSX CBE1000 6.0 PBN1000A 4.8 REMOTE BLOWER CIRCUIT DIAGRAM...
  • Page 24 www.zephyronline.com DESCRIPTION PART # Replacement Parts 6W Bloom™ HD LED Light Bulbs (each) Z0B-0034 Baffl e Filter (each) 50210022 Optional Accessories Duct Cover Extension Z1C-00TP Single Internal Blower CBI-290A / CBI-600A External Blower CBE-1000 In-Line Blower PBN-1000A To order parts, please visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 25 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows:...
  • Page 26 Trapeze CTP-E48BSX CTP-E54BSX CTP-E60BSX Numéro de modèle Numéro de série Date d’achat Détaillant JAN14.0101 © Zephyr Corporation LISEZ ET CONSERVEZ CES INSTRUCTIONS LISEZ ET CONSERVEZ CES INSTRUCTIONS...
  • Page 27 www.zephyronline.com...
  • Page 28 MISE EN GARDE DE SÉCURITÉ ......... LISTE DU MATÉRIEL ..............INSTALLATION Feuille de calcul pour le conduit ......Espace libre et hauteur de montage ....Options d’installation pour le conduit ....Spécifi cations de la hotte ......... Préparation du ventilateur 9-11 ........
  • Page 29 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 30 ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. CETTE HOTTE N’EST PAS CONÇUE POUR UNE UTILISATION AVEC UN GRIL EXTÉRIEUR ATTENTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.
  • Page 31 MODÈLES: CTP-E48BSX, CTP-E54BSX, CTP-E60BSX 1 - Hotte 2 - Filtres défl ecteurs 4 - Ampoules DEL HD de 6W Zephyr Bloom 2 - Pièces de recouvrement de conduit télescopiques 4 - Tiges de support télescopiques 4 - Coupleurs de tige de support télescopique...
  • Page 32 Longueur x Pièces de conduit Longueur x Pièces de conduit Total Total Nombre utilisé Nombre utilisé 3-1/ 4” x 10” 1 pi 6” 30 pi rect., droit embout mural circ./registre 6” circ., droit 1 pi 6” 30 pi chapeau de toiture circ.
  • Page 33 www.zephyronline.com Lorsqu’il est possible de le faire, diminuez TOUJOURS le nombre de pièces et de changements de direction. Si un long tronçon de conduit est nécessaire, augmentez le diamètre du conduit. Si vous utilisez un raccord réducteur, installez un long raccord, et non un réducteur à...
  • Page 34 AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée.
  • Page 35 www.zephyronline.com Vue de haut Vue de côté 32” Recouvrement de conduit standard Min 34” - Max 51 1/2” Pièce de prolongement Z1C-00TP Min 47” - Max 72” 15-3/4” Support de plafond Vue de face 11-3/4” 10” 13/16” 9” 1/2” 5/8” 12-1/8”...
  • Page 36 PRÉPARATION DU VENTILATEUR INTERNE 1. Retirez du boîtier du moteur la bride du 2. Fixez le ventilateur interne à la bride du ventilateur interne, fi xée en place à l’aide de 6 ventilateur interne à l’aide de quatre vis M4*16 (de la trousse de quincaillerie du ventilateur vis.
  • Page 37 www.zephyronline.com PRÉPARATION DU VENTILATEUR INTERNE (SUITE) 8. Branchez le connecteur Molex à six broches du 7. Fixez le boîtier du moteur à la hotte avec douze câble du condensateur au connecteur Molex à vis M4*6. six broches de la boîte de commande. Branchez la fi...
  • Page 38 PRÉPARATION DU VENTILATEUR À DISTANCE (SUITE) 4. Fixez le collier circulaire de départ de 8” du 3. Fixez le fi l de mise à la terre c.a. et le fi l de ventilateur à distance à la bride du ventilateur à mise à...
  • Page 39 www.zephyronline.com Languettes Ajoutez des blocs de bois Languettes Support de plafond FIG. 1 Plafond Trous de montage Marque pour coupleur Trou de montage de la vis d’ajustement AVANT Encoches pour FIG. 2 câblage électrique 1. Déterminez le lieu d’installation de la hotte. Tracez des lignes centrales de l’avant à l’arrière et de gauche à droit de l’endroit où...
  • Page 40 FIG. 4 FIG. 3 7. Déterminez la hauteur d’installation désirée de la hotte, puis mesurez et choisissez les supports à angle de 27-3/8” ou de 35-3/8”. Placez et fi xez les supports à angle de type A et B au boîtier du moteur (comme illustré) à...
  • Page 41 www.zephyronline.com Installation des tiges télescopiques Vis d’ajustement 1. Installez les tiges télescopiques dans les coupleurs du dessus de la hotte et fi xez-les en place avec une vis M4*4. 2. Déployez la tige télescopique intérieure jusqu’aux coupleurs du plafond et fi xez chaque tige avec une vis d’ajustement M4*4.
  • Page 42 Afficheur (Vitesse, arrêt à retardement) Ventilateur Marche/Arrêt Arrêt à retardement (15 min.) Choix de 3 vitesses Lumières Allumer/Veilleuse/Éteindre Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous mettez l’appareil en marche, le ventilateur et les lumières s’allument aux mêmes réglages que lorsque vous l’avez éteint. Lorsque vous éteignez l’appareil, toutes les fonctions s’éteignent, y compris les DEL et la veilleuse.
  • Page 43 www.zephyronline.com Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant, que vous installiez votre hotte avec le mode d’évacuation ou de purification d’air. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres.
  • Page 44 La commande à distance radioélectrique est munie d’un aimant pour un entreposage facile. La commande peut être mise sur n’importe quelle surface magnétique, comme un réfrigérateur ou le support à commande Zephyr (FIG. 4). Le support à commande peut s’installer à une prise électrique standard pour un rechargement facile.
  • Page 45 www.zephyronline.com ENTRETIEN DES SURFACES: Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. N’utilisez pas de produits à blanchir au chlore ou d’agents nettoyants «...
  • Page 46 PROCÉDURES DE DÉPANNAGE POUR LA HOTTE TRAPEZE Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
  • Page 47 www.zephyronline.com Ampérage maximal VOLTS CTP-E48/54/60BSX CBI290A 0.8 CBI600A 2.7 Schéma de câblage du ventilateur interne Boîtier Blanc Jaune Rouge Moteur Bleu Noir Blanc Vent-H Vent-M Vent-L Lampe Boîtier DEL2 PC de commande Remarques :Condensateur 3uF 250VCA ADAPTÉ CA120V 60Hz (CBI-290A) Condensateur 25uF 250VCA ADAPTÉ...
  • Page 48 VOLTS Ampérage maximal CTP-E48/54/60BSX CBE1000 6.0 PBN1000A 4.8 Schéma de câblage du ventilateur à distance Boîtier Vert Blanc Blanc Jaune Noir Moteur Rouge Bleu Rouge Bleu Noir Blanc Vent-H Vent-M Vent-L Lampe Boîtier DEL2 PC de commande Remarques :Condensateur 15uF 370VCA ADAPTÉ CA120V 60Hz (CBE-1000) Condensateur*2 25uF 250VCA ADAPTÉ...
  • Page 49 DESCRIPTION Nº DE PIÈCE Pièces de remplacement Ampoules DEL HD de 6W Zephyr Bloommd (unité) Z0B-0034 Filtre défl ecteur (unité) 50210022 Accessoires optionnels Pièces de recouvrement de conduit Z1C-00TP Ventilateur interne simple CBI-290A / CBI-600A Ventilateur externe CBE-1000 Ventilateur de conduit PBN-1000A Pour commander des pièces, visitez-nous en ligne au www.zephyronline.com ou...
  • Page 50 Zephyr Corporation (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présen- tes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...