Zephyr zna-e42s ventilation hood user manual (21 pages)
Summary of Contents for Zephyr Okeanito COK-E42SX
Page 1
Okeanito CO K-E36SX iiim CO K-E42SX CO K-E48SX Model number: Serial number: Date of Purchase: Sales Dealer: 00COK-70001 07/05Rev:2Q Zephyr Corporation.
Page 4
CAUTION To Reduce the Risk of Fire and Electric Shock. Install This Range Hood Only with Remote Blower Models C B E-IO00 Rated Maximum6,2 amp, 120 Vac 60Hz or Jntecjral Blowers Manufactured by Zephyr Ventilation, Models CB 1-600.
Page 6
Duct pieces i Equivalent number Duct pieces i Equivalent number ::length x used Total 31/4"x10" 1Ft. Rect., wall cap 6" Round 30 Ft. straight with damper ..7" Round, i 1 Ft. straight roof6" Round,cap ii30 Ft. ) = i 7"...
Page 7
Minimum mount height between range top to hood bot- tom should be no less than 28". 32" Max 52" Maximum mount height should be no higher than 36". It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard;...
Page 8
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/certified Silver Tape or DuctTape. Some Ducting Options:...
Page 10
ATTENTION The following are intructions for installing internal blower model CBI-600. For instructions on preparing for external blower model CBE-1000 please turn to page "10". Before installing, verify that motor spins freely, € The internal blower kit consists of the blower 1.
Page 11
5.Remove existing grounding screw a nd 6.Re-attach grounding screw t ofinish attach g rounding wire from capacitor box. installation ofcapacitor box. Refer toFig-A o n previous page, 7.Attach short capacitor connector toblower 8.Attach l ong c apacitor connector tocontrol board c onnector. connector, 10.
Page 12
ATTENTION The following are intructions on preparing your hood for installation with external blower model CBE-1000. For instructions on installing internal blower model CBI-600 please turn to page "8". The external blower kit consists of an 8" 1. Remove screws from internal flange. collar, and external blower wiring box.
Page 13
6.Position cover onto external blower 7.Secure cover tobox with provided screw. wiring b ox. 8.Attach connector from external blower 9.Attach g rounding wire from external blower wiring b ox t ocontrol board b ox connector wiring b ox t ogrounding screw ofthe junction inside h ood.
Page 14
DuctCover CeilingBracket DuctCover CeilingBracket C _21" 14 1/2" min28" max36" Attachscrewsto ceilingbracket 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line. 3. Mark mounting height, line B (14 1/2" from line A). This is the top of the hood. 4.
Page 15
gap between bracket and wall C I°°°°°°°°°°°°°°°°°°°°°i Bottom Attach screws to both sides of the duct covers and secure to ceiling bracket. Electrical 1. Place wall bracket on line C. Position top of wall bracket so it is even with the 21" mounting spread Make sure bracket is attached to wall as shown in the diagram.
Page 16
Front Back 1. Attach utensil rail to hood canopy. A small hole has been pre-drilled into the canopy to provide a starting point to attach the first utensil rail post. After the first post is lined up with the hole, gently slide the rest of the rail onto the canopy, (note: be careful not to scratch the stainless steel when performing this step, this is why there is a starter hole), 2, Attach a short set screw into each post in order to hold utensil rail onto canopy.
Page 17
NOTE: The following instructions describe the installation of the CBE-1000 external blower for use with Zephyr models CTR COK or CSH range hoods only, Fig-5 24 II /4" 5 5/8" 30" >d[_71/2" 5/8" 3/4" Fig-1 TYPICAL iNSTALLATiON ROOF M OUNT OUTSIDE WALL MOUNT 10"...
Page 18
1. Remove and discard shipping brackets and wood support (attached to sides of motor and inlet collar). Fig. - 7 BEFORE INSTALLING, check to see if blower wheel turns freely and does not rub on motor brackets. Check damper door to be sure it moves freely and spring returns door to closed position, 2.
Page 19
6. Run electrical conduit per local code to conduit outlet in bottom plate of blower (use liquid tight connection). Other end of conduit will connect to external blower wiring box in you Zephyr hood. See installation instructions earlier in manual for wiring location.
Page 21
Filter Clean Reminder (Standard Baffle Filters fitted): A set of baffle filters are fitted by the factory, These Baffle Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are req_ to be kept clean, The Filter Clean Reminder function in the microprocessor will automatically indicate by a _ye:_@ flashing when the metal filters need to be cleaned after...
Page 22
SurfaceMaintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface, For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain.
Page 23
Replacing LightBulbs: Make sure all power is turned off and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip together, the light socket will now protude from the hood allowing you to remove the bulb. (Be careful when releasing retain clip as it is under pressure to hold it in place) Replacement halogen bulbs are available at most stores which sell light bulbs.
Page 24
What to do iSSUe CatlS8 After installation, the unit 1. Make sure the circuit breaker and the unit's 1. The power source is not turned ON. power is ON. doesn't work? 2. The power line and the cable locking connector 2.
Page 25
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instruc- tions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr's Authorized Agents. What is Not Covered: Consumable parts such as light bulbs, filters, and fuses.
Page 26
Part Description Part# Halogen Bulb G U-10, 120V, 50W ZOB-O020 Incadescent Bulb T29 127V 40 W 7303000009 AccessoryDescription Part# "O Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-OOOK N=,=...