  • Page 1 Trapeze CTP-E 48SX CTP-E54SX CTP-E 60SX Model number: Serial number: Date of Purchase: Sales Dealer: MAY07.0101 © Zephyr Corporation.
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE ..........LIST OF MATERIALS ........INSTALLATION Ducting Calculation Sheet ....... Mounting Height and Clearance ..... Ducting ..............Specifications ............Internal Blower ............ 8 - 9 Preparing Hood for External Blower ....Mounting the Hood ..........11 - 14 FEATURES &...
  • Page 4 CAUTION To Reduce the Risk of Fire and Electric Shock, Install This Range Hood Only with Remote Blower Models C B E-1000 Rated Maximum 6.2 amp, 120 Vac 60Hz or Integral Blowers Manufactured by Zephyr Ventilation, Models C B I-600.
  • Page 5 MODEL: CTP-ExxS 1 - Hood 2 - Ba e Filters 4 - G U-10, 120V 50 W, halogen bulbs 2 - Utensil Rails 2 - Telescopic Duct Covers 4 - Telescopic Rods Sets 4 - Angle Bra ckets (27 3/8”) 4 - Angle Bra ckets (35 3/8”) 1 - Ceiling Mounting Bra cket 1 - Internal Flange...
  • Page 6 www.zephyronline.com Equivalent number Equivalent number Duct pieces Duct pieces length x used Total length x used Total 3 1/4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 7” Round, 1 Ft. 6” Round, 30 Ft. straight roof cap 7”...
  • Page 7: Damage - Shipment/Installation

    Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount height should be no higher than 36". It is important to install the hood at the proper mounting Min 34"-Max 52" height. Hoods mounted too low could result in heat damage and re hazard;...
  • Page 8 www.zephyronline.com WARNING FIRE HAZARD NEV E R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certi ed Silver Tape or DuctTape. Some Ducting Options: External Blower side wall cap...
  • Page 9 9“ 32“ 15 3/4” 26 5/8” 11 3/4“ 32” 10“ 9“ 2” Min 21” - Max 40” 7/64” 12 1/8” 13/32” 2” 48” , 54” , 59 1/8”...
  • Page 10 www.zephyronline.com ATTENTION The following are intructions for installing internal blower model CBI-600. For instructions on preparing for external blower model CBE-1000 please turn to page “10”. Before installing, verify that motor spins freely. The internal blower kit consists of the blower 1.
  • Page 11 6. Attach junction box to internal ange using 7. Attach grounding wires from junction box provided 1/2” self tapping screws and 4mm and motor to grounding screw as shown. internal diameter washers. 8. Place blower with attached ange into 9. Attach using 1/2” self tapping screws to motor housing as shown on Fig-A.
  • Page 12 www.zephyronline.com ATTENTION The following are instructions on preparing your hood for installation with external blower model CBE-1000. For instructions on installing internal blower model CBI-600 please turn to page “8”. The external blower kit consists of an 8” 1. P osition and attach external blower wiring collar, external ange and external blower box and junction box using provided 1/2”...
  • Page 13: E L E Ctrical - Warning

    Ceiling Mounting Holes Marking for Coupler Narrow End Tabs Add Blockings Tabs Ceiling Bracket Using the cardboard template from top of box, mark the center point in between the (4) mounting holes. Determine the location for mounting your hood, place template on ceiling and mark/drill the center point for the ceiling mounting bracket and the foud corner holes where the telescopic rod couplers will attach to the ceiling.
  • Page 14 www.zephyronline.com 1. Mount motor housing to the range hood b ody using (10) 1/2” self tapping screws. 2. Determine height of hood, measure and select either 27 3/8” or 35 3/8” angle brac kets and attach (4) of them to the motor housing using (8) 1/2” self tapping screws (2) for each angle bracket. 3.
  • Page 15 Duct work Electrical wiring 5. Lift assembled unit and attach all (4) angle brackets to ceiling bracket. Make sure the tabs on each angle brackets are facing the outside. The angle brackets will t between the slots on the ceiling bracket. One half of the angle bracket will be on the outside of the ceiling bracket and the other half will be on the inside of the ceiling bracket.
  • Page 16 www.zephyronline.com Telescopic Rod Installation 1. Install telescopic rod (thicker end down) into coupler screws on top of hood and secure with medium set screw. Attach screw using provided tool. 2. Extend telescopic rod towards the ceiling and insert thin end of rod into ceiling coupler. Attach a medium set screw in the middle where the two rods attach to each other.
  • Page 17 www.zephyronline.com 1. Blower On/O By pressing , the blower is switched On and O . 2. Speed Selection The 3 speed levels are selected by presing to decrease and to increase speed level. T he display indicates level selected. 3. Delay O This is used for programmed shut down of blower and lights 15 minutes after the function is activated.
  • Page 18: Re-Setting Function

    Filter Clean Reminder (Standard Ba e Filters tted): A set of ba e lters are tted by the factory. These Ba e Filters are intended to lter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will automatically indicate by a ashing when the metal lters need to be cleaned after...
  • Page 19: Surface Maintenance

    Remove lters by sliding away from center of hood and pulling down. Dry lters and re-install before using hood. Replacing Ba e Filters Should lters wear out due to age and prolonged use, contact Zephyr to purchase replacements.
  • Page 20 R eplacing Light Bulbs: CAUTION: Light bulbs become extremely hot when turned on. DO NOT touch bulbs until switched o and cooled. Touching hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip together, the light socket will now extend from the hood allowing you to remove the bulb.
  • Page 21 www.zephyronline.com s s I After installation, the unit 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. doesn’t work? 2. The power line and the cable locking connector is 2.