www.zephyronline.com
Tornado II
AK8200AS
Tornado III
AK8300ASX
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
MAY12.0701 © 2012 Zephyr Corporation
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr Tornado II AK8200AS

  • Page 1 Tornado II AK8200AS Tornado III AK8300ASX Model number: Serial Number: Date of Purchase: Sales Dealer: MAY12.0701 © 2012 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE LIST OF MATERIALS INSTALLATION Ducting Calculation Sheet Mounting Height & Clearance Ducting Options Specifi cations Electrical Installing the Power Pack Single and Dual Internal Blowers Remote Blower Preparation FEATURES & CONTROLS Touch Controls RF Remote Control MAINTENANCE Cleaning and Installing Filters Lights TROUBLESHOOTING LIST OF PARTS AND ACCESSORIES...
  • Page 4 READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product. AK8200AS - 710W, 5.95 Amps AK8300ASX (CBI-290B / CBI-600B) - 217W, 1.85 Amps / 460W, 3.85 Amps AK8300ASX (PBI-1100A / PBN-1000A/CBE-1000) - 780W, 6.55 Amps / 840W, 7.3 Amps...
  • Page 6 MODELS: AK8200AS AND AK8300ASX PARTS SUPPLIED AK8200AS 1 - Power Pack 2 - Baffl e fi lters 2 - Halogen light bulbs (pre-installed) 1 - Dual internal blower (pre-installed) 1 - 8” round adapter 1 - RF remote control (with battery)
  • Page 7 Equivalent number Duct pieces length x used 3-1/ 4” x 10” 1 Ft. Rect., straight 6” Round, 1 Ft. straight 7”-10” Round, 1 Ft. straight 3-1/ 4” x 10” 15 Ft. Rect.90 elbow 3-1/ 4” x 10” 9 Ft. Rect.45 elbow 3-1/ 4”...
  • Page 8 If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range. AK8200AS Vertical Ducting: 8” round minimum (dual blower) Horizontal Ducting: AK8300ASX Vertical Ducting: 6”...
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options side wall cap w/ gravity damper...
  • Page 10 ” ” ” ” ” 15/16 ” 13/16 AK8200AS front AK8200AS/AK8300ASX ” ” ” ” ” 7/16 AK8300ASX front *note: 8” round transition is only needed if using power pack with a dual internal or external blower. www.zephyronline.com elec. ”...
  • Page 11: Electrical

    ELECTRICAL WARNING All Electrical work must be performed by qualifi ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
  • Page 12 1. Install blower into Power Pack AK8200AS - Blower is pre-installed AK8300ASX - Refer to page 11 for instructions Remove support screw from top of Power Pack before installing into cabinet. FIG 2b 2.
  • Page 13: Remote Blower Preparation

    MULTIPLE BLOWERS ARE COMPATIBLE WITH AK8300ASX ONLY. AK8200AS INCLUDES A 1000 CFM DUAL BLOWER ONLY. FOR REMOTE BLOWER PREPARATION INSTRUCTIONS TURN TO PAGE 12. 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16”...
  • Page 14 1. Place 8” round adapter on top of power pack and secure with (4) M4x8 screws. Connect 8” round duct work to 8” round adapter. 3. Place cap over threaded end of remote blower wiring and secure by turning clockwise. A: Ground wire screw location (inside) 5.
  • Page 15: Touch Controls

    Lights On/Dim/Off 5 Min Delay Off Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower turns on at the same speed it was switched off at. When switched off the entire hood powers off, including the lights. Speed Selection The 3 speed levels are selected by pressing display indicates speed level selected.
  • Page 16 Baffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory, These baffle filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
  • Page 17 The RF remote control is equipped with a magnet for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder. Maximum remote control communication distance from power pack is 15 feet.
  • Page 18 2. Pivot back of fi lter upwards so it is angled in the power pack. 3. Push fi lter into channel on back of power pack to lock into place. Replacing Baffl e Filters: Hood Model: Part No. Qty. to Order AK8200AS 50210010 AK8300ASX 50210010 www.zephyronline.com FIG 4...
  • Page 19 Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen. For Zephyr part numbers please turn to page 19 of the manual. Bottom View...
  • Page 20: Troubleshooting

    TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III Issue Cause After installation, 1. The power source is not turned ON. the unit doesn’t work. 2. The power line and the cable locking connector is not connecting properly. 3. The switch board and control board wirings are disconnected.
  • Page 21 DESCRIPTION Replacement Parts Light Bulb MR16 (GU10) 35W (each) Baffl e Filter (each) Remote Control Optional Accessories Liner,36” (AK8200AS) Liner,42” (AK8200AS) Liner,48” (AK8300ASX) Liner,54” (AK8300ASX) Liner,60” (AK8300ASX) To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 22 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows: Ten Year Limited Warranty for Parts: For ten years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.