www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary. COK-E36BSX, COK-E42BSX w/CBI-290A - MAX 170 Watts, 1.4 Amps COK-E36BSX, COK-E42BSX w/CBI-600A - MAX 400 Watts, 3.3 Amps COK-E36BSX, COK-E42BSX w/CBE-1000 - MAX 795 Watts, 6.7 Amps...
Equivalent number Equivalent number Duct pieces Duct pieces length x used Total length x used Total 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7” Round, 1 Ft. 6”- 8” Round, 30 Ft.
www.zephyronline.com If turns or transitions are required; install as far away from opening and as far apart, between 2, as possible. Minimum mount height between range top and hood bottom should be no less than 28”. x . B x . D Maximum mount height should be no higher than 36”.
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape. Some Ducting Options External Blower...
ELECTRICAL WARNING All Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
www.zephyronline.com INTERNAL BLOWER PREPARATION 2. Secure internal blower to internal blower fl ange 1. Position internal blower inside hood body so by (4) M4*16 screws from internal blower internal blower collar proturdes though 6” round hardware. fl ange opening. 3. Position capacitor box inside hood body and 4.
www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the hood. 6 ” C / L 14-1/2” FIG. 2 9-11/16” gap between min. 28” bracket and wall max. 36” Bottom FIG. 1 FIG. 3 1.
Page 15
10. Attach wall bracket to wall by (3) M4*1-1/2” screws with washers. NOTE: Wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check with local codes for compliance. Failure to use suitable wall anchors and screws to hold the weight of the hood could result in personal injury or damage to the cooking surface or counter.
www.zephyronline.com Display (Speed level, Delay Off Indicator) Blower On/Off 15 Min Delay Off Mood Light On/Off Adjust 3 Speed Levels Lights On/Dim/Off Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower and lights turn on at the same setting they were switched off at.
Baffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory, These baffle filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scoring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain.
TROUBLESHOOTING PROCEDURES FOR OKEANITO Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
www.zephyronline.com DESCRIPTION PART # Replacement Parts Light Bulb 6W LED (each) Z0B-0035 Baffl e Filter (each) 50210019 Optional Accessories Duct Cover Extension Z1C-00OK Single Internal Blower CBI-290A / CBI-600A External Blower CBE-1000 In-Line Blower PBN-1000A To order parts, please visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
Page 23
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain Limited Warranty service under warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you”...