Download  Print this page

Zephyr CPA-E42ASX Use, Care And Installation Manual

Zephyr cpa-e42asx ventilation hood user manual
Hide thumbs

Advertisement

Model number:
Numéro de modèle: ____________________________________
Número de modelo:
Serial number:
Numéro de série: _____________________________________
Número de serie:
Date of Purchase:
Date d'achat:
Fecha de compra:
Sales Dealer:
Détaillant:
Distribuidor:
LI2ZRA - DEC06.0101

READ AND SAVE THESE INSTRUCTIONS

LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
LEA Y GUARDE ESTAS INSTRUCCIONES
Padova
CPA - E42ASX
CPA - E48ASX
CPA - E54ASX
_____________________________________
_____________________________________
www.zephyronline.com

Advertisement

Table of Contents
loading

  Related Manuals for Zephyr CPA-E42ASX

  Summary of Contents for Zephyr CPA-E42ASX

  • Page 1: Read And Save These Instructions

    Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Numéro de série: _____________________________________ Número de serie: Date of Purchase: Date d’achat: Fecha de compra: Sales Dealer: Détaillant: Distribuidor: LI2ZRA - DEC06.0101 READ AND SAVE THESE INSTRUCTIONS LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES LEA Y GUARDE ESTAS INSTRUCCIONES Padova CPA - E42ASX...
  • Page 2 English page French page Spanish page APPROVED FOR RESIDENTIAL APPLIANCES READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
  • Page 3: Table Of Contents

    Important Safety Notice ... 5 Electrical & Installation Requirements ... 6 Electrical requirements ... 6 Before installing the hood ... 6 List of Materials ... 7 Parts supplied ... 7 Parts not supplied ... 7 Dimensions and Clearances ... 8 Ducting Options and Examples ...
  • Page 4 Installation - Installing the Duct Covers ... 18 Installation - Hanging the Hood onto the Wall ... 19 Installation - Electrical Connection & Final Installation Steps ... 20 Electrical connection ... 20 Description of the Hood ... 21 Features & Controls - Touch Controls & Features ... 22 Description of control panel ...
  • Page 5: Important Safety Notice

    READ AND SAVE THESE INSTRUCTIONS CAUTION FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B.
  • Page 6: Electrical & Installation Requirements

    ELECTRICAL REQUIREMENTS IMPORTANT Observe all governing codes and ordinances. It is the customer’s responsibility: To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
  • Page 7: List Of Materials

    To reduce the risk of fire and electric shock, install this rangehood only with integral blowers mod. EBI-600B manufactured by ZEPHYR or with external blowers mod. CBE-1000, manufactured by ZEPHYR. And with front panels mod. CPC-0012 (42" SS); mod. CPC-0112 (42" Brass); mod. CPC-0018 (48" SS); mod. CPC- 0118 (48"...
  • Page 8: Dimensions And Clearances

    Only for version with top discharge feature: * Hood with external motor: Over this measurement a hole may be made on the rear section for the passage of the discharge pipe for connection to the external motor. Consult the template for the passage of pipes under this measurement. ** Hood with external motor: Above this measurement a hole may be made on the rear panel for the outward passage of the discharge pipe.
  • Page 9: Ducting Options And Examples

    www.zephyronline.com Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS This range hood is designed to exhaust fumes and vapours towards the outside and is ready to be fitted with an internal blower and for discharge towards the top side (Vertical discharge).
  • Page 10: Installation - Ductwork Calculation Sheet

    Duct pieces Equivalent number lenght x used = 3 1/4 ” x 10” 1 Ft. Rect., straight 6 ” Round,, 1 Ft. straight 7", 8” 1 Ft. Round,, straight 3 1/4 ” x 10” 15 Ft. x ( Rect.90° elbow 3 1/4 ”...
  • Page 11: Installation - Preliminary Operations

    Attention! The installation requires several steps where is asked to temporarily remove some particulars and screws, We recommend to record and keep all of these components in a safe place ready to be used as required. • Remove stainless mesh filters (See relative paragraph on Maintenance section of this manual).
  • Page 12: Installation - Internal Blower

    Note: for External blower installation disregard the instruction in this page and step ahead on page 14. TOP DISCHARGE (Vertical discharge) The hood is ready to be used for vertical discharge, proceed to install the internal blower (See next page). REAR DISCHARGE (Horizontal discharge) •...
  • Page 13: Internal Blower Installation

    INTERNAL BLOWER INSTALLATION • Fit the blower inside the hood. • Install the blower to the support with 4 screws (Provided), check that the rectangular outlet of the blower matches with the rectangular slot of the support. Note: The 4 fixing screws must be screwed in from the outside of the hood (See photo below).
  • Page 14: Installation - External Blower Preparation

    Note: for internal blower installation, disregard the instruction on this next page and consult the instruction on the previous pages (See pages 12-13). Note 2: Refer to the CBE-1000 manual for instructions on mounting the external blower to a roof or exterior wall. The manual is available on our website and is included in the external blower packaging.
  • Page 15: External Blower Electrical Connection-Preliminary Operations

    • Install the supplied round transition collar to the previously installed cover/round transition support plate. Align and attach with 2 screws securely. EXTERNAL BLOWER ELECTRICAL CONNECTION - PRELIMINARY OPERATIONS Installing the external blower junction box • Remove the electrical knock out on the upper panel. See diagram below.
  • Page 16: Installation - Front Panel

    • To attach front panel to hood body, align the 8 threaded studs through the front bodies corresponding holes. Use 8 wing nuts to attach and secure. See diagrams below NOTE: The front panel is not supplied with the range hood and must be purchased separately.
  • Page 17: Installation

    INSTALLING THE HOOD ONTO THE WALL 1. Disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Use a thick, protective covering over countertop, cooktop or range to protect from damage and debris. Select a flat surface for assembling the unit.
  • Page 18: Installation - Installing The Duct Covers

    13. Optional duct cover installation: a. Remove the support bracket from the Duct Cover assembly and attach it to the ceiling with 2 drywall anchors and screws Note: The printed index on the bracket must match the center line previously drawn (See installation step 2).
  • Page 19: Installation - Hanging The Hood Onto The Wall

    14. For internal blower installation ONLY: a. Horizontal (Rear) discharge: Install from the outside the 3 1/4 ” x 10” Rect. transition on the outlet hole of the blower with 3 screws. b. Vertical (Upper) discharge: Install from the outside the 8" plastic round transition, with 4 screws.
  • Page 20: Installation - Electrical Connection & Final Installation Steps

    18. Electrical connection WARNING Electrical Shock Hazard Warning: Turn off power circuit at the service panel before wiring this unit. 120 VAC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE.
  • Page 21: Description Of The Hood

    www.zephyronline.com 1 Controls 2 Baffle filter 3 Halogen lamp 4 Incandescent ambient lamp 5 Hood body 6 Duct cover...
  • Page 22: Features & Controls - Touch Controls & Features

    Use the high suction speed in cases of concentrated kitchen vapors. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes after terminating cooking.
  • Page 23: Features & Controls - Baffle Filters Change Indicator

    Filter Clean Reminder (Standard Baffle Filters fitted): A set of baffle filters are fitted by the factory. These Baffle Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will automatically indicate by a every 30 hrs.
  • Page 24: Maintenance

    ATTENTION! Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply. CLEANING The cooker hood should be cleaned regularly internally and externally. Use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks.
  • Page 25: Replacing The Mood Lighting Bulb

    www.zephyronline.com REPLACING THE MOOD LIGHTING BULB: To replace mood lighting bulb, remove baffle filter from hood. To access lamp area, remove the two threaded knobs that fix the cover. Unscrew mood lighting bulb counter-clockwise and replace with a standard max. 40W, type T10, 125V-130V medium base bulb.
  • Page 26: Trouble Shooting

    Issue After installation, the 1. The power source is not turned ON. unit doesn’t work? 2. The power line and the cable locking connector is not connecting properly. 3. The switch board and control board wirings are disconnected. 4. The switch board or control board is defective.
  • Page 27: List Of Parts And Accessories

    Part Description Halogen Bulb, 120V 50 W Filter Baffle Part Description Internal Blower 600 CFM External Blower 1000 CFM Front Panel 42" SS Front Panel 42" Brass Front Panel 48" SS Front Panel 48" Brass Front Panel 54" SS Front Panel 54" Brass Doluflex 6pc.