Traction Circuit Is Inoperative; Cutting Reel Circuit Is Inoperative - Toro Greensmaster eFlex 1800 Service Manual

Hide thumbs Also See for Greensmaster eFlex 1800:
Table of Contents

Advertisement

Traction Circuit Is Inoperative

NOTE: The parking brake latch has to be released, the
operator presence control has to be engaged and the
speed control has to be above the zero speed position
before the traction circuit will operate.
Possible Causes
Traction switch is not adjusted correctly or is faulty.
Speed control potentiometer is faulty.
Parking brake latch switch is not adjusted correctly or
is faulty.
Wire harness connections or wires are loose or
damaged.
A problem exists with the traction or reel drive system.
Electric motor is faulty (NOTE: Fault should be
displayed on InfoCenter if electric motor is faulty).

Cutting Reel Circuit Is Inoperative

Possible Causes
Reel engage switch is not adjusted or is faulty.
Wire harness connections or wires are loose or
damaged.
Electric motor is faulty (NOTE: Fault should be
displayed on InfoCenter if electric motor is faulty).
Greensmaster eFlex 1800/2100
Correction
Use InfoCenter Diagnostics screen to check traction
switch operation. Adjust or replace traction switch if
necessary.
Use InfoCenter Diagnostics screen to check speed
control potentiometer operation. Check and repair
speed control potentiometer and circuit wires if
necessary.
Use InfoCenter Diagnostics screen to check parking
brake latch switch operation. Adjust or replace parking
brake latch switch if necessary.
Check electrical connections. Repair wire harness as
necessary.
Refer to Chapter 3 -- Traction and Reel Drive System.
Use InfoCenter Faults and Diagnostics screens to
check reel circuit operation. Check electric motor and
circuit wires. Repair as necessary.
Correction
Use InfoCenter Diagnostics screen to check reel
engage switch operation. Adjust or replace reel
engage switch if necessary.
Check electrical connections. Repair wiring as needed.
Check electric motor and circuit wires. Repair as
necessary.
Page 4 - - 13
Electrical System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster flex 21000404304042

Table of Contents