Setting The Service Parameters - ATTACK DPX15 Instructions For Use Manual

Dpx wood gasifying boiler standard / profi / lambda
Hide thumbs Also See for DPX15:
Table of Contents

Advertisement

3.6 SETTING THE SERVICE PARAMETERS

By holding the OK button you get into the service menu to the parameter settings (the icon
(13)). The buttons „+" and „–" are used to browse in particular parameters. After selecting the
appropriate parameter, it is confirmed by „OK" button and starts to flicker. To exit the menu,
confirm the [End] by „OK" button. After remaining for more than 1 minute without the user´s
intervention, the controller switches the display to the basic mode.
Table 3. Service parameters:
SERVISCE MENU (available by holding the OK button)
Display Parameter
Π100
Maximum fan output
n 40
Minimum fan output
Πh 5
Ratio of changing the fan rotations
Automatic regulation of changing the fan rotations
Πr 0
Delay of changing the fan rotations
Πt 1
Πn 5
Frequency of exhaust fan blow-through
Πu 6
Duration of exhaust fan blow-through
Πd3
Duration of manual fan operation for 100%
r100
Fan output by ignition
rh 5
Hysteresis of boiler stop by ignition
P 30
Temperature to start the circuit pump
Ph 2
Hysteresis of circuit pump
Interval of unlock function of circuit pump
Pc --
ur4
Operation of additional output
u30
Operating temperature of D.H.W. tank or accumulation tank
uh 5
Hysteresis of D.H.W. tank of accumulation tank
Boiler temperature increase by D.H.W. warming
uP 5
L65
Minimum boiler temperature
H 85
Maximum boiler temperature
h 2
Boiler temperature hysteresis
Temperature of boiler overheating
A 99
Fd60
Duration of boiler stop by ignition and fuel shortage
Fb30
Duration of boiler stop by flue shortage and burn-down
Ar 0
Control of multifunctional additional output
Adjusted flue gas temperature
c 240
c h5
Flue gas temperature hysteresis
c t 5
Time constant of stabilization the flue gas temperature
c F10
Blower speed jump while stabilizing flue gas temperature
Flue gas temperature by fuel shortage
c 90
Maximum flue gas temperature
c 300
Prod
Reset of production settings
outΠ
Test of fan relay
outP
Test of circuit pump relay
outu
Test of relay of optional pump
outr
Test of additional output
End
Exit to main menu
Min
Max
Step Prod. set.
1
100
1%
1
100
1%
2
20
1
–, 0
10
1
0
99
1
--, 5
60
1s
1
99
1min
--, 1
99
1min
1
100
1%
1
45
1 °C
--, 20
70
1 °C
1
40
1 °C
--, 1
99
1min
0
4
1
30
60
1 °C
1
30
1 °C
1
20
1 °C
30
65
1 °C
80
95
1 °C
1
10
1 °C
90
99
1 °C
--, 1 99–4h 1min
--, 1 99–4h 1min
0
1
1
–0,5
250
1 °C
1
99
1 °C
1
99
1 min
1
20
1 °C
30
150
1 °C
250
400
1 °C
outΠ out1
outP out2
outu out3
outr
out4
100
40
5
0
1
5
6
3
100
5
30
2
2
4
30
5
5
65
85
2
99
60
30
0
240
5
5
10
90
300
23