Setting Of Boiler Parameters - ATTACK ELECTRIC EASY Series Instructions For Use Manual

Wall hung electric boiler
Table of Contents

Advertisement

Setting /termination of mode LE:
Reduce the temperature requested on the control panel
by pushing the button
on the display there is LE, confirm it
now in the mode Summer.
If you don't confirm your setting by pushing , the boiler
turns to setting before.
Stop the operation mode summer by pushing
setting the heating water temperature and by its
confirmation
. The boiler heats now in the operation
mode heating water (see the point 2.3.1).
2.3.4 Operation mode Stand-by (РГ)
The boiler doesn't heat and also doesn't heat service
utility water. There is only the antifreeze function on (if it
is not blocked by the parameter 4) and deblocking pump
function (1x per day pump turning through). We
recommend using this function in case of putting the
boiler out of the operation to elongate pump life time and
protect heating system against freeze.
Going to the operation mode Stand-by: (РГ):
Push the button
for a long time (minimally 3 s, during
this period on the display there is lighting Пl) and the
boiler got to the operation mode Stand-by, on the display
now there is lighting РГ. If you want to go back to setting
point, push shortly the button .

2.4. Setting of boiler parameters

Summary of parameters:
Setting of parameters:It is necessary to push
shortly the button
for setting all the parameters
(operation mode of heating water, operation mode of
service utility water or operation mode Summer. Using
parameter
pump running out:
0=none; 1=time running out;
Π1
2=temperature running out
Π2
time of pump running out
Π3
temperature of pump running out
Π4
antifreeze protection: 0=NO; 1=YES
Π5
regulation constant P
Π6
regulation constant I
Π7
temperature hysteresis
to 30° C and after next pushing
and you are
and by
specification
the buttons , and choose the number of parameter
you want to set. By pushing
value of the parameter. By its confirmation, by pushing
the new value of the parameter is now in memory
and the boiler turns back to the mode before setting
with new parameters set by the user.
The user is able to set only parameters 1 4.
Parameters 5
service man or by a producer and are blocked.
Description of parameters:
Пl - option of pump type running out after termination of
request for heating.
†0 - there is not and pump running out, the pump is
switched off with a last heating element
†1 - pump running out is controlled by the parameter 2
set and after termination of request for heating the time
is counting down till switching off the pump
†2 - pump running out is controlled by the temperature
of heating water set by the parameter 3 and after
termination of request for heating the pump is on till the
temperature of heating water fall down on the
temperature value set.
П2 - setting of time of pump running out after
termination of request for heatingí.
П3 -setting of temperature of heating water that the
pump is in operation in after termination of request for
heating.
П4 - ON/OFF antifreeze function (see the chapter safety
functions).
П5 - setting of the value of regulating constant P, setting
only by a producer!
П6 - setting of the value of regulating constant I, setting
only by a producer!!
П7 - setting of hysteresis for the temperature in ° C
value setting
producer
scale
setting
0, 1, 2
1
1 to 30, step 1
4
25 to 70,step 1
40
0, 1
1
1 to 20
6
1 to 50
3
1 to 10
2
you are able to set the
7 could be set only by an authorized
responsible person for
unit
setting
-
user
min.
user
°C
user
-
user
-
producer
-
producer
°C
authorized service man.
13