The „←" button is used to exit from menu and then is the display automatically switched to the
operating mode. If no button is pressed for 30 minutes, the display automatically is switched to
the operating mode automatically.
If any fault occurs or the temperature rises extremely, the options menu closes automatically.

4.12 INFORMATION DISPLAYED:

Menu
Submenu
Boiler set
°C
Boiler temperature
°C
Flue gas set
°C
Flue gas temperature
°C
O
set
2
%
O
2
%
CO
set
2
%
CO
2
%
Suction fan
Circuit pump
Information
Primary motor
%
Secondary motor
%
Lambda
Efficiency
ETA – F (%)
Total temperature excess (%)
Temperature excess –
10 loadings (%)
Operating hours
H
Software
Serial number
Test
of
device
Safety test
Setting
END
32
Indication
Indicates the adjusted temperature value in the boiler
--
Current value. Indicates the current boiler temperature.
---.-
Indicates the adjusted flue gas temperature
---.-
Indicates the current flue gas temperature
---.-
Indicates the adjusted oxygen value in the flue gas.
--.-
Indicates the current oxygen value in the flue gas.
--.-
Indicates the adjusted value of the CO
--.-
Indicates the current value of the CO
--.-
Note: The fix value of the CO
Operating state of the fan
ON/OFF
Operating state of the pump
ON/OFF
Position of the primary air flap
--.-
Position of the secondary air flap
--.-
Ratio of air (current value) Note: The fix value of the CO
--.-
calculation is max. 20,3 %.
Grade of efficiency of burning – current value
--.-
Temperature of air for burning (35 °C) is used for calculation
Total ratio of the temperature excess (%) during the total time of
--.-
burning (total of the operating hours)
Ratio of the excessive temperature in (%) by the last 10 loadings.
--.-
Operating hours of the boiler. After 60 000 hours is the counter
--.-
deleted.
Program version nr.
--.--
Serial or production number of the regulator.
---------
in the flue gas
2
2
for calculation is max. 20,3 %.
2
for
2