END
After the settings are done, the test of device is performed, its correct functionality is checked
and the safety test is made.
34
06 : Disconnection
O
2
TAG
10 : V1 primary air
Air (%)
85
11 : V2 secondary air
Air (%)
40
Function: The boiler for wood burning turn off
after burning out due to
O
– indicates higher amount of the rest coal
2
(easier start)
TAG – indicates the minimum rest coal
(recommended by problems with burning –
shapeless or wet fuel)
Producer: O
2
Setting: O
/TAG
2
Function: When there is a flue gas sensor or
oxygen fault, it is regulated to the adjusted
value. This is a temporary solution until the
fault is removed – it is not a normal operating
function!
Producer: 85 %
Range for setting: 0 % – 100 %
Function: When there is a flue gas sensor or
oxygen fault, it is regulated to the adjusted
value. This is a temporary solution until the
fault is removed – it is not a normal operating
function!
Producer: 40 %C
Range for setting: 0 % – 100 %