Oxygen sensor (Lambda probe)
Terminal 1: Sensor −
Terminal 2: Sensor +
Terminal 3: Sensor warming
Terminal 4: Sensor warming

Temperature sensor

Air flap V1 – V2, circuit pump, suction fan
Terminal 3: Connection
Terminal 4: Connection 24V~
Terminal 5: Regulation signal sec. Y+ (0/2 – 10V)
Terminal 6: Regulation signal prim. Y+ (0/2 – 10V)
56
Terminal 1: Flue gas sensor F1 Pt100
Terminal 2: Flue gas sensor F1 Pt100
Terminal 3: Boiler sensor F2 Pt100
Terminal 4: Boiler sensor F2 Pt100
Terminal 5:
Terminal 6:
Values of the resistance:
T = 0 °C R = 100,0 Ω
T = 20 °C R = 107,8 Ω
T = 100 °C R = 138,5 Ω
T = 200 °C R = 175,8 Ω
4-wire flexi cable covered by
silicone with the section of
conductor of 0,75 mm
white = warming 12 V≈
black = + signal of sensor
grey = − signal of sensor
Fix the flue gas sensor into the flue connection
by the bayonet flange!
Do not extend the connection conductors of
the sensors!
Treat the boiler sensor and the safety
thermostat sensor by a warm-water paste, put
it into the casing and fix by a spring!
Polarity is not important.
Use the 3-wire flexi cable with the
section of 0,75 mm
circuit pump and the suction fan
C: STARTING CAPACITOR
Terminal 12: L: Circuit pump
Terminal 13: N: Circuit pump
Terminal 14: PE: Circuit pump
Terminal 15: L: Suction fan
Terminal 16: N: Suction fan
Terminal 17: Free
Terminal 18: PE: Suction fan
2
2
to connect the