Maintenance and Servicing
5.5.3

Cleaning the suction filter

Check the function of the suction filter Fig. 24-17 daily and clean it as
required.
1. Remove the suction filter from the neck.
2. Clean the suction filter under running water.
3. Mount the suction filter on the neck again.
5.5.4

Checking the gasket at the drain hose

Fig. 25:
Check the function of the gasket at the drain hose Fig. 25-A daily, replace it
after 125 operating hours at the latest.
After use, check the drain hose for soiling and clean if necessary.
5.5.5

Checking the gasket in the tank cap

A
Fig. 26:
Check the function of the gasket in the tank cap Fig. 26-C daily and replace it
if damaged.
When replacing the gasket:
• Ensure that the installation position is correct.
• Ensure that the gasket is pressed fully into the groove.
• Ensure that the gasket is seated correctly.