4.3.2.7.3. If "Ltd" was selected then a limited uses counter C.01 to C.04 is
4.3.2.7.4.If "OLA" was selected (applies only to a RSH) then the "No" or
4.3.2.8. The various options presented in level n+4 depend on what was selected in
level N+3. For example:
4.3.2.8.1.Depending on whether CH.1 or CH.2 was selected then its
4.3.2.8.2. Depending on which of the "APb" levels L.01 to L.07 was
4.3.2.8.3. If "OLA" was selected (applies only to a RSH) then the "No" or "YEs" (or
4.3.2.9. Once "Con" and, optionally, heads H.01 to H.31 are set, it is critical that -A- in
level n+1 is selected (i.e. present and hold the "Admin" tag) to save all the
settings that may have been made. The system will flash up the text "ScS" (an
abbreviation for success) if the tag, or tags, under this ID are updated, and will
revert back to the start by displaying "Id".
4.3.3. Update by "tAg". If update by "tAg" was selected then the display will look as
follows:
4.3.3.1. Present the tag to be updated.
4.3.3.2. The display will indicate "Con" (see part 2 of 2 on the Update Menu)
first chosen by scrolling vertically through the list C.01 to C.04 (or
"---" if exit to the previous level is required) by presenting and
removing the "Admin" tag. The resultant choice is selected by
presenting and holding the "Admin" tag for 5 seconds.
"Yes", (or "---" if exit to the previous level is required) selection is
made by presenting and removing the "Admin" tag. "No" means
that the head will NOT allow a tag to operate at the RSH when the
head is off line (i.e. not linked via the RS485 network). "Yes"
specifies that the head will permit valid tags to operate, even off-
line.
associated relay can be set to be "On" or "OFF" by scrolling
vertically through the options "On", "OFF" (or "---" if exit to a
previous level is required) by presenting and removing the
"Admin" tag. The selection is confirmed by presenting and holding
the "Admin" tag for 5 seconds.
previously selected, the choice of whether this reader is at the
"entrance" or "exit" to an APB zone, defined by the "In" or "Out"
selection respectively, is made by scrolling vertically through the
options "In", "Out" (or "---" if exit to a previous level is required) by
presenting and removing the "Admin" tag. The selection is
confirmed by presenting and holding the "Admin" tag for 5
seconds.
"---" if exit to the previous level is required) selection is made by
presenting and removing the "Admin" tag. "No" means that the head
will NOT allow a tag to operate at the RSH when the head is off-line
(i.e. not linked via the RS485 network.) "YEs" specifies that the head
will permit valid tags to operate, even off-line. Depending on which of
the counters "C.01" to "C.04" was previously selected the choice of
whether this counter must be operational for this reader is selected by
scrolling vertically through the options "On", "OFF" (or "---" if exit to a
previous level is required.)