tag. The resultant choice is selected by presenting and holding the "Admin"
tag for 5 seconds.
1.2.5.2. If "APb" was selected then an anti-pass back level L.01 to L.07 is first chosen
by scrolling vertically through the levels L.01 to L.07, or "---" if exit to a
previous menu is required) by presenting and removing the "Admin" tag.
The resultant choice is selected by presenting and holding the "Admin" tag
for 5 seconds.
1.2.5.3. If "Ltd" was selected then a limited use counter C.01 to C.04 is first chosen
by scrolling vertically through the list C.01 to C.04, or "---" if exit to the
previous level is required) by presenting and removing the "Admin" tag.
The resultant choice is selected by presenting and holding the "Admin" tag
for 5 seconds.
1.2.5.4. If "OLA" was selected (applies only to a LSH) then the "No" or "Yes", or "---"
(if exit to the previous level is required) selection is made by presenting and
removing the "Admin" tag. "No" means that the head will NOT allow a tag
to operate at the LSH when the head is off line (i.e. not linked via the RS485
network). "Yes" specifies that the head will permit valid "OLA" tags to
operate, even off-line.
1.2.6. The various options in level 6 depend again on what was selected in level 5. For
example.
1.2.6.1. Depending on whether CH.1 or CH.2 was selected then its associated relay
can be set to be "On" or "OFF" by scrolling vertically through the options
"On", "OFF", or "---" if exit to a previous level is required) by presenting and
removing the "Admin" tag. The selection is confirmed by presenting and
holding the "Admin" tag for 5 seconds.
1.2.6.2. Depending on which of the "APb" levels L.01 to L.07 was previously
selected, the choice of whether this reader is at the "entrance" or "exit" to an
APB zone, defined by the "In" or "Out" selection respectively, is made by
scrolling vertically through the options "In", "Out", or "---" (if exit to a
previous level is required) by presenting and removing the "Admin" tag.
The selection is confirmed by presenting and holding the "Admin" tag for 5
seconds.
1.2.7. Once the attributes of "Con" and, optionally, heads H.01 to H.31 are set, it is critical
that -A- in level 3 (see section 1.2.3.1.) is selected (i.e. present and hold the new
tag presented in 1.2.3 ) to save all the settings that may have been made to levels 4
onwards to all the readers.