Using the "Normal Learn Menu Structure" as a guide, the following steps are followed
fo Normal Learn.
1.2.1. The "Admin" tag is presented and held (for 5 seconds) to get from "Lrn" of the
Main menu to where the display indicates "000". i.e from the Main menu to
Level 1.
1.2.2. The "Admin" tag is again presented and removed to get the display to increase, or
decrease, (as described above) until the required ID is reached. (Level 1 to Level
2)
1.2.3. A "new" tag is now presented which moves the display from level 2 to level 3. The
change from level 2 to level 3 is shown by the fact that the ID shown as numeral
"026" in this example, changes to "Con" (abbreviation for Controller). This
indicates that the system will now allow any of the configuration options of levels
4, and onwards, to be set up on the L1000 reader. Two routes can now be
followed:
1.2.3.1. If the "Admin" tag is presented and removed, the display will scroll
vertically through the list showing any connected readers, indicated as
"Con" (for the L1000 Controller) and "H.01" to "H.031" (for any LSH's
physically attached to the RS485 network). This enables the settings of
levels 4 and onwards to be set individually on any attached reader.
After the last attached head is shown the display indicates -A-. This is
the display symbol to indicate SAVE or EXIT. Once "Con" and,
optionally, heads H.01 to H.31 are set, it is critical that -A- is selected
(present and hold the "NEW" tag) to save all the settings that may have
been made to levels 4 onwards to all the readers.
1.2.3.2.. Once a reader is selected (as per 1.2.3.1. above), the display is moved
from level 3 to level 4 by presenting and holding the "Admin" tag. e.g.
if "Con" is displayed and the "Admin" tag is presented and held (for at
least 5 seconds) the display will change from "Con" to "ASC".
1.2.4. Similar to level 3 it is possible to scroll vertically through the "ASC" (associa-
tions), "APb" (anti-pass back), "Ltd" (Limited uses counters), "OLA" (Off-Line
Access), or "- - -" (Exit back to previous level) by presenting and removing
the "Admin" tag. Once a specific menu item in level 4 is decided upon, the
display is moved, horizontally, from level 4 to level 5 by presenting and
holding the "Admin" tag for 5 seconds. E.g. if "ASC" is displayed and the
"Admin" tag is presented and held for 5 seconds then the display changes
from "ASC" to "CH.1"
NOTE: The OLA Menu will only appear for LSH's. It does not apply to the
L1000.
1.2.5. The various options presented in level 5 depend on what was selected in level
4. For example:
1.2.5.1. If "ASC" was selected then channel 1 or 2 (only channel 1 can be selected
for LSH's) is first chosen by scrolling vertically through Ch.1, Ch.2, or "---" if
exit to a previous level is required), by presenting and removing the "Admin"
NOTE: If the "Admin" tag is presented at -A- the system will exit
back to the main menu without saving any changes.