Configure Menu - Centsys Lattice Installation Manual

Table of Contents

Advertisement

2.3.3.6. If delete by "tAg" is required move to level 4 by presenting and holding the

3. Configure Menu

The third main menu item is the "CFg" or configure menu. This menu provides the user the ability to
configure the following parameters on the various readers:
AUS - Advanced User Structure
The configure menus are described fully below referring to the "Configure" Menu (Figures 25 to 28)
Description of the Configure Menu
3.1. The "Admin" tag is presented and held (for 5 seconds) to get from "CFg" of the Main menu to
where the display indicates "HdS" (Head Settings) which is the first sub-menu item of the
Configure Menu.
3.2. The various sub-menu items can be selected by scrolling vertically through the list by
presenting and removing the "Admin" tag. The following menus are selectable.
•HdS - Head Settings which allows for setting of relay energise timers, alarm timers, buzzer
volume, etc.
• dSP - Display Brightness which can be adjusted in 10% increments. The default is 50%
• CUS - Complex User Structure. This selects whether the advanced user menu is turned
on or off.
• AtC - Advanced Tag Control. Allows for creation of additional "Admin" tags.
• bnr - Backup and restore. This allows the controller memory to be backed up to, or
restored frm, the optional backup memory module.
• PCS - P.C. System menu. This allows the user to specify whether or not the system is
connected to a P.C.
• SUP - This is a diagnostic tool which displays the current supply voltage to the controller.
• "---" - Exit to previous menu
3.3. Once a decision is made of which menu item in level 1 is required, present and hold the
"Admin" tag for 5 seconds to move to level 2.
3.4. The specifics of each sub-menu item described in 2.1 to 2.5 is described more fully below.
3.4.1. Hd - (Head settings): If HdS was selected the display will indicate "Con". This sub-menu
allows the parameters of the main controller (L1000) or any of the attached LSH's (i.e.
H.01 to H31) to reset. Select which reader (head) needs to be set by presenting and
If an ID needs to be deleted from this head (remember it will not be
deleted from other heads) present and hold the "Admin" tag until the green
LED swops to the red LED. All tags stored under this ID on this head are now
deleted. If these tags were deleted from the L1000 they will in future display as "ASC"
and not show their old ID number.
"Admin" tag. The following is displayed
2.3.3.6.1. Present the tag that needs to be deleted.
2.3.3.6.2. The display flashes up the tag ID number, and the red LED, to
indicate that the tag is deleted from this head.
NOTE: If a tag has been deleted from the L1000 controller (i.e.
Con), then it will display in normal run mode as "ASC" on the
L1000 in future, indicating that it is NOT associated with this head.
It will still operate at other heads.
Page 38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents