The following illustration shows the I/O ports on the rear of your server.

Parallel port

Your server has one parallel port. This port supports three standard Institute of
Electrical and Electronics Engineers (IEEE) 1284 modes of operation: Standard Parallel
Port (SPP), Enhanced Parallel Port (EPP), and Extended Capability Port (ECP).
Viewing or changing the parallel-port
assignments
You can use the built-in Configuration/Setup Utility program to configure the
parallel port as bidirectional, that is, so that data can be both read from and written to
a device. In bidirectional mode, the server supports the ECP and EPP modes.
To view or change the parallel-port assignment:
1.
2.
3.
4.
5.
64
IBM® xSeries 350: User's Reference
Advanced System Management
Interconnect port A
Advanced System Management
Interconnect port B
Serial A
Mouse
Keyboard
Serial B
Restart the server and watch the monitor screen.
When the message Press F1 for Configuration/Setup appears, press F1.
Note: The Devices and I/O Ports choice appears only on the full configuration
menu. If you set two levels of passwords, you must type the administrator
password to access the full configuration menu.
From the main menu, select Devices and I/O Ports; then, press Enter.
Select the parallel port; then, use the arrow keys to advance through the available
settings.
Note: When you configure the parallel port as bidirectional, use an IEEE 1284-
compliant cable. The maximum length of the cable must not exceed 3
meters (9.8 feet).
Select Save Settings; then, select Exit Setup to exit from the Configuration/Setup
Utility main menu.
Management port C
Video
USB 1
Ethernet
USB 2
Parallel