Code
Function
089
Microprocessor
100
IBM® xSeries 350: User's Reference
Result
Failed
Invalid microprocessor in slot xyz or BIOS setup
problem
(where xyz identifies the microprocessor that is
causing the error message)
Processor in socket id xyz is installed but not
functioning
(where xyz identifies the microprocessor that is
causing the error message)
Microprocessor in socket id xyz
(where xyz identifies the microprocessor that is
causing the error message)
Note:
The microprocessor-error light
associated with the microprocessor will
be lit.
Processor in socket id xyz is defective
(where xyz identifies the microprocessor that is
causing the error message)
Text message
Action
1.
Check the system
error log for the
related error
messages.
2.
If your server does
not have the latest
level BIOS installed,
update the BIOS.
3.
If the problem
persists, replace the
xyz microprocessor
and run the test
again.
If the problem persists,
call for service.
1.
Reseat the
microprocessor.
2.
If the problem
persists, replace the
microprocessor.
If the problem persists,
call for service.
Replace the
microprocessor.
If the problem persists,
call for service.