IBM eserver xSeries 350 User Reference Manual page 113

Hide thumbs Also See for eserver xSeries 350:
Table of Contents

Advertisement

Code
Function
089
Microprocessor
165
Service processor Failed
175
System thermal
180
Status display
Result
Failed
Test setup error: Application microprocessor not
installed or BIOS setup problem
VRM corresponding to Microprocessor in socket
xyz is defective
(where xyz identifies the microprocessor whose
VRM is causing the error message)
VRM corresponding to Microprocessor in socket
id xyz is not installed
(where xyz identifies the microprocessor whose
VRM is causing the error message)
Advanced System Management Processor on
system board
Failed
Fan # n
(where n is the number of the failing fan)
Note:
The fan LED on the diagnostic LED
panel will be lit.
Temperature sensed on system board is out of
range
Failed
Diagnostic LED panel
Operator information panel
LED on hot-swap SCSI backplane
LED on processor board
LED on system board
Text message
Action
1.
Verify that the
Application
microprocessor is
installed and seated
correctly.
2.
Check the system
error log for related
error messages.
3.
If your server does
not have the latest
level BIOS installed,
update the BIOS.
4.
If the problem
persists, replace the
application
microprocessor and
run the test again.
If the problem persists,
call for service.
Replace the VRM.
If the problem remains,
call for service.
Install a VRM.
If the problem persists,
call for service.
Call for service.
Replace the indicated fan.
If one of the fan LEDs on
the diagnostic LED panel
is on, replace the
indicated fan. If the
problem persists, call for
service.
Call for service.
Chapter 6. Solving problems
101