Installing A Hot-Swap Power Supply - IBM eserver xSeries 350 User Reference Manual

Hide thumbs Also See for eserver xSeries 350:
Table of Contents

Advertisement

Installing a hot-swap power supply

identify pins 1, 2, and 3 on the system board, see the illustration of the jumper blocks
on the system board on page 58.
To change a jumper position for a three-pin jumper block:
1.
Turn off the server; then, disconnect all power cords and external cables.
2.
Remove the server cover (see "Removing the server top cover and bezel" on page
41).
3.
Lift the jumper straight off the pin block.
4.
Align the holes in the bottom of the jumper with the center pin and the pin that
was not covered previously.
5.
Slide the jumper fully onto these pins.
6.
Reinstall the server cover, and connect the cables (see "Installing the server top
cover and bezel" on page 62).
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label
attached.
Chapter 5. Installing options