Table 20. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet
controller.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-086 The driver parameter block is too small.
Explanation: The driver parameter block is too small.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The device driver media parameter block is too small.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-091 The hardware configuration conflicts.
Explanation: You tried to load a new frame type for the existing controller. The hardware
assumptions made in doing so are incorrect. This error can also occur if you try to specify a
mode (such as redundancy) that conflicts with another specified mode.
Action: Make sure that your hardware configuration matches the software settings.
PCNTNW-NW-126 The group bit in the node address override was cleared.
Explanation: The IEEE address has a group bit that indicates that an address belongs to a
group of stations. This bit is used only as a destination address; it cannot be used as a source
address. You tried to enter a source address with this bit set. The device driver cleared the
group bit of the source address.
Action: None necessary, message is for information only.
PCNTNW-NW-127 The local bit in the node address override was set.
Explanation: The local bit in the IEEE address format indicates that the addresses are being
managed locally. If you use the node address override capabilities of this device driver to
enter a new address, the local bit must be set. You entered an address without the local bit set.
The device driver has set the local bit.
Action: None necessary, message is for information only.
PCNTNW-NW-164 The device was not found.
Explanation: The driver cannot find an Ethernet controller in the server.
Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go
to "Starting the diagnostic programs" on page 96 to run the diagnostic programs.
PCNTNW-NW-165 The device was not found at IOADDRESS.
Explanation: The Ethernet controller cannot be found at the specified I/O address.
Action: The Ethernet controller does not require a parameter for the I/O address. Remove the
I/O address parameter.
PCNTNW-NW-167 PCI scan specified, device not found.
Explanation: The device driver cannot locate the Ethernet controller on the PCI bus.
Action: Verify that the Ethernet controller is enabled. If the problem persists, see "Starting the
diagnostic programs" on page 96 and run the diagnostic programs.
PCNTNW-NW-180 The DMA parameter is not necessary for PCI device.
Explanation: The Ethernet controller does not require a DMA setting.
Action: None necessary; message is for information only.
Chapter 6. Solving problems