IBM eserver xSeries 350 User Reference Manual page 122

Hide thumbs Also See for eserver xSeries 350:
Table of Contents

Advertisement

Table 17. Light Path Diagnostics.
System error
Diagnostics
LED (on the
panel LED on
information LED
panel)
On
PCIB
On
PCIC
On
DASD
On
MEM
110
IBM® xSeries 350: User's Reference
Cause
An error occurred on PCI bus B. An
adapter in PCI slot 2, 3, 4 or the
system board caused the error.
An error occurred on PCI bus C. An
adapter in PCI slot 5 or 6 or the system
board caused the error.
A hot-swap hard disk drive has failed
on SCSI channel B.
A memory error occurred.
Action
1.
Check the error log for additional
information.
2.
If you cannot correct the problem
from the information in the error
log, try to determine the failing
adapter by removing one adapter
at a time from PCI bus B (PCI
slots 2, 3, and 4) and restarting
the server after each adapter is
removed.
If the problem persists, have the
system serviced.
1.
Check the error log for additional
information.
2.
If you cannot correct the problem
from the information in the error
log, try to determine the failing
adapter by removing one adapter
at a time from PCI bus C (PCI
slots 5 and 6) and restarting the
server after each adapter is
removed.
If the problem persists, have the
system serviced.
1.
Check the error log for additional
information. If the error log
indicates a temperature problem
and the fans are working
correctly, check for air flow
blockage.
2.
If the amber hard disk drive
status LED on one of the hot-
swap hard disk drives is on, see
"Turning on the server" on page 7
for more information.
1.
Check the DIMM error LEDs on
the memory board.
2.
Replace the DIMM indicated by
the lit DIMM error LED.

Advertisement

Table of Contents
loading

Table of Contents