Table 23. UNIX LLI driver messages for the Ethernet controller.
pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris device driver has been reset because of a device fault.
Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic
programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
•
•
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
•
Modify your hardware settings.
•
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify your hardware settings. Run the NETCONFIG program to search for another
Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify your hardware settings.
pnt0-24
add_intr_handler failed! Vector already shared at different IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
•
Modify your hardware settings.
•
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-26
The DMA number is not necessary for PCI device.
Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
pnt0-29
The IRQ number is already in use.
Explanation: The specified I/O address is already in use.
Action: Run the NETCONFIG program to modify your hardware settings.
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.