IBM eserver xSeries 350 User Reference Manual page 137

Hide thumbs Also See for eserver xSeries 350:
Table of Contents

Advertisement

Table 23. UNIX LLI driver messages for the Ethernet controller.
pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris device driver has been reset because of a device fault.
Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic
programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify your hardware settings. Run the NETCONFIG program to search for another
Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action: Modify your hardware settings.
pnt0-24
add_intr_handler failed! Vector already shared at different IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-26
The DMA number is not necessary for PCI device.
Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
pnt0-29
The IRQ number is already in use.
Explanation: The specified I/O address is already in use.
Action: Run the NETCONFIG program to modify your hardware settings.
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
Chapter 6. Solving problems
125

Advertisement

Table of Contents
loading

Table of Contents