4.9
Removing the EFC trim switch
4.9.1
Remove ash-pan, fret assembly / trim or fascia from the front of the fire.
4.9.2
Isolate the gas supply, disconnect the gas control valve to bulkhead
pipe and pilot / thermcouple connections to the pilot. Remove the fire
from the opening.
4.9.3
Pull controls sub assembly forward, disconnect the trim switch lead from
the control board, remove the EFC mounting frame from the fire.
4.9.4
Remove the EFC trim switch from mounting frame via the self adhesive
pad, disconnect the wiring loom.
4.9.5
Replace in reverse order and carry out a gas tightness test.
4.10
Parts Shortlist
Replacement of parts must be carried out by a competent person such as a GAS
SAFE registered gas installer. The part numbers of the replaceable parts are as
follows, these are available from BFM Europe, address and contact details as
shown on the back page of this book.
Complete fuel-bed / ceramic set
L/H front ceramic
R/H front ceramic
L/H rear ceramic
R/H rear ceramic
Glass panel
EFC control switch
EFC control switch lead
RC gas control valve
RC control board
RC battery cable
RC battery holder
Piezo igniter
NG manual gas valve
LPG manual gas valve
800mm extended flue duct (for use with NG models only)
27
B-130100
B-130060
B-130070
B-130080
B-130090
B-128040
B-152610
B-152650
B-106790
B-129140
B-106810
B-106820
B-1320NG
B-102880
B-102960
CV-MARLT