ATLANTA
DECORATIVE RADIANT
NATURAL VENT GAS FIRE
Installation and Maintenance Instructions
Hand these instructions to the user
Model No. FAVRU0MN is only for use on Natural Gas (G20) at a
supply pressure of 20 mbar in G.B. & I.E.
Supplied By www.heating spares.co Tel. 0161 620 6677

Advertisement

Table of Contents
loading

Summary of Contents for Flavel Atlanta FAVRU0MN

  • Page 1 ATLANTA DECORATIVE RADIANT NATURAL VENT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. FAVRU0MN is only for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B. & I.E. Supplied By www.heating spares.co Tel. 0161 620 6677...
  • Page 2: Table Of Contents

    CONTENTS PAGE Section 1 Information and Requirements Appliance Information Conditions of Installation Flue and chimney suitability Fireplace / surround suitability Shelf position Flue / chimney inspection Fire place opening and chimney catchment Fitting to fireplaces with existing chair-brick and conventional brick-built chimneys Fitting to pre-cast flue installations Fitting to pre-fabricated twin wall metal flue boxes 1.10 Hearths...
  • Page 3: Information And Requirements

    SECTION 1 INFORMATION AND REQUIREMENTS 1.0 APPLIANCE INFORMATION Main injector (1 off) Stereomatic Injector Elbow Size 62 Pilot Type Copreci 21100/141 Max. Gross Heat Input: 4.7 kW Min. Gross Heat Input: 2.5 kW Gas Rate: 0.44 m Cold Pressure: 20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.) Ignition Push-button Piezo...
  • Page 4: Conditions Of Installation

    INSTALLATION REQUIREMENTS 1.1 CONDITIONS OF INSTALLATION It is the law that all gas appliances are installed only by a CORGI Registered Installer, in accordance with these installation instructions and the Gas Safety (Installation and Use) Regulations 1998 as amended. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to comply with the law.
  • Page 5: Shelf Position

    1.4 SHELF POSITION The fire may be fitted below a combustible shelf providing there is a minimum distance of 200mm above the top of the fire and the shelf does not project more than 150mm. If the shelf overhangs more than 150mm the distance between the fire and the shelf must be increased by 15mm for every 25mm of additional overhang over 150mm.
  • Page 6: Fire Place Opening And Chimney Catchment

    1.6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fireplace must be between 380 and 425 mm wide, and between 550 and 565mm high. If the opening exceeds these dimensions then a surround must be constructed from suitable non-combustible material to produce a correct size opening.
  • Page 7: Fitting To Pre-Cast Flue Installations

    1.8 FITTING TO PRE-CAST FLUE INSTALLATIONS To install the fire box in to pre-cast flue starter blocks, there must be at least 105mm from the mounting face of the fire to the rear of the pre-cast flue starter block to allow sufficient space for debris collection.
  • Page 8: Installation Of Fire

    SECTION 2 INSTALLATION OF FIRE 2.1 UNPACKING THE FIRE Carefully lift the fire out of the carton. Remove the loose item packaging carefully from the front of the appliance. Check the contents as listed :- Packing Check List 1off Fire box / burner assembly 1off Trim 1off...
  • Page 9 d) The gas supply can be bought in to the firebox from either the left-hand rear or the left-hand side. e) Carefully withdraw the firebox from the opening to enable the gas supply and fire fixing to be completed. f) The inlet pipe should be connected to the isolating / inlet elbow of the appliance using 8mm rigid or semi-rigid metal tubing.
  • Page 10 g) Fit the wallplugs provided and screw the fixing eyes securely into the rear of the fire opening. If the clearance at the rear of the fire is at the minimum specified for a precast flue application, it may be necessary to bend over the fixing eyes after screwing them fully into the rear of a pre-cast starter block.
  • Page 11: Gas Tightness And Burner Pressure

    m) Evenly tighten the tensioning nuts to tension both cables and pull the fire snugly against the wall. Do not overtighten, it is only necessary to pull the seal up against the sealing face of the wall, it does not need to be compressed. Check that there are no gaps behind the seal. n) With the fire securely in place, if a concealed gas connection has been made through either of the access holes in the sides of the fire, the holes should be closed around the pipe to prevent leakage of air through the gap around the pipe.
  • Page 12: Lighting The Appliance

    SECTION 3 COMMISIONING LIGHTING THE APPLIANCE WARNING If the fire goes out for any reason or is turned off and it is necessary to relight the fire it is important to allow the fire to cool for 3 minutes before attempting to re-light it. a) Turn on the gas restrictor at the inlet fitting.
  • Page 13 Smoke match position. d) If spillage persists, the flue is not functioning correctly and a fault exists. If, after investigation the fault cannot be traced and rectified, the fire must be disconnected from the gas supply and expert advice obtained. e) If there is an extractor fan fitted anywhere in the vicinity of the appliance, the spillage test should be repeated with the fan running on maximum and all interconnecting doors open.
  • Page 14: Maintenance

    Servicing Notes • Servicing should be carried out annually by a competent person such as a CORGI registered engineer. This is a condition of the Flavel guarantee schemes. • The service should include visually checking the chimney and fire opening for accumulations of debris and a smoke test to check for a positive up-draught in the chimney.
  • Page 15: Removal Of The Pilot Assembly

    REMOVING THE OXY-PILOT ASSEMBLY Note: Because this appliance is fitted with an atmosphere sensing ‘Oxy-Pilot’ it is not possible to replace the thermocouple separately, because the thermocouple position is factory set to a tight tolerance. Any replacement of parts on the pilot requires a complete new pilot assembly.
  • Page 16: Cleaning

    With the allen key provided remove the 4 allen bolts, loosening each one a small amount at a time to prevent stressing the glass panel, then lift the glass frame clear. Refit the glass panel to the fire in reverse order, again tightening each Allen bolt a small amount at a time to prevent stressing the glass panel.
  • Page 17 REPLACEABLE PARTS Replacement of any parts must be carried out by a competent person such as a CORGI registered gas installer. Replacement Pilot Assembly Part No. B-38930 Supplied By www.heating spares.co Tel. 0161 620 6677...
  • Page 18: Cfm Europe Ltd

    Due to our policy of continual improvement and development the exact accuracy of illustrations and descriptions contained in this book cannot be guaranteed Part no. 84-38080 Issue 7 CFM Europe Ltd. Trentham Lakes Stoke-on-Trent Staffordshire ST4 4TJ www.cfm-europe.com Telephone 01782 339000 Telephone (Service (08700) 101187 Supplied By www.heating spares.co Tel.